RRU3269
Installation Guide
9 Installing RRU Cables
Issue Draft B (2018-05-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
110
Figure 9-21
Installing an RRU alarm cable
Install the waterproof DB15 male connector on the RRU alarm cable with caution, preventing the pin
assignment from being damaged.
Step 3
Use an M3 Phillips screwdriver to tighten the posts on both sides of the waterproof DB15
male connector to 0.4 N·m (3.54 lbf·in.).
Step 4
Connect the eight cord end terminals at the other end to external alarm devices.
Remove insulated protective tubes from the cord end terminals before connecting the cord end
terminals to devices, as shown in Figure 9-22.
Use insulating adhesive tapes to wrap cord end terminals that are not in use and fix them at a proper
position based on the onsite situations. This prevents false alarm reporting and equipment damage
due to contact of exposed cables. Figure 9-23 shows the method for handling cord end terminals not
in use.