DBS3800 Product Description
Issue V0.1 (2009-11-27)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
36
≤
19 kg (with the rack and housing)
Rated voltage
Operating voltage
Input power
–48 V DC
–36 V DC to –57V DC
-40°C to +50°C (with solar radiation)
Temperature
-40°C to +55°C (without solar radiation)
Relative
humidity
5% to 100%
Air pressure
70 kPa to106 kPa
Storage
ETSI EN 300 019-1-1 V2.1.4 (2003-04) Class 1.2: "Weather protected,
not temperature-controlled storage locations"
EMC
The DBS3800 meets the EMC requirements and complies with the
following standards:
R&TTE Directive 99/5/EC
3GPP TS 25.113 V4.4.0 (2002-12)
ETSI EN 301 489-1 V1.2.1 (2000-08)
ETSI EN 301 908-1 V2.2.1 (2003-10)
Transportation
ETSI EN 300019-1-2 V2.1.4 (2003-04) Class 2.3: "Public transportation"
Note1: In 1001 configuration, two carriers are configured discontinuously, and the interval between
two frequencies is 10 MHz.
Note 2: As recommended in 3GPP TS25.104, the receiver sensitivity is measured at the antenna port
on the top of the cabinet on condition that the channel rate reaches 12.2 kbit/s and the BER is within
0.001.
Note 3: The receiver sensitivity (median performance over reception bandwidth) is tested at the
antenna port on the top of the cabinet. The AMR speech service should be at 12.2 kbit/s and the BER
should not exceed 0.001.