l
The label on the PDF side is marked with B03- -48V2. It indicates that the cable is for
-48V2 DC supply and is connected to the cabinet in row B, column 03.
This topic describes how to label a PGND DC cable.
Procedure
Step 1
Obtain an engineering label and a label plate, as shown in
.
Figure 3-80
Label and label plate
A05 PGND
Label Plate
Label
Step 2
Attach the label in the center of the plate.
NOTE
You can attach the label on either side of the plate. Consistency, however, must be maintained in actual
situations.
Step 3
Bind the cable tie 20 mm [0.79 in.] away from the plug, as shown in
NOTE
By default, the label is attached 20 mm [0.79 in.] away from the connector. If required, you can change
the position to facilitate smooth installation. Consistency and neatness, however, must be maintained.
Figure 3-81
Binding the cable tie
A05 PGND
Step 4
Tighten the cable tie to attach the label, as shown in
HUAWEI NetEngine80E Router
Installation Guide
3 On-site Cable Assembly and Installation
Issue 02 (2011-09-10)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
66