Installation Manual
Quidway Eudemon200 Firewall
Chapter 1 Overview
1-4
1. RPU Slot0
2. Interface Module Slot1
3. Interface Module Slot2
4. ESD-preventive wrist strap jack
Figure 1-1
Front panel of the Eudemon200 firewall
1. Fan module
2. Grounding screw
3. AC power interface
4. Power switch
5. Power supply unit 2 (PWR2)
6. PWR1
7. ESD-preventive wrist strap port
Figure 1-2
Rear panel of the
Eudemon200 firewall
The Eudemon200 firewall has three slots on the front panel, with slot 0 for the RPU and
slots 1 and 2 for interface modules.
Two power supply units (PSU), working in 1+1 backup mode can be horizontally
installed in the Eudemon200 firewall from the rear of the chassis. Both the AC-input
PSU and the DC-input PSU are available, and you may make selection as needed. The
fan module is located at the left rear. The PSU and fan module are both hot swappable.
At the bottom left of the rear panel is an ESD-preventive wrist strap port and at the top
right is a grounding screw.