Parameters
Keyword and Value Description
Default Value
-i HyperImage ID
The HyperImage ID. The value ranges from 0 to
127.
You can query the information by running the
showhyimginfo
command.
None.
-l speed level
The rollback speed. The value ranges from 1 to 4.
l
1 stands for low.
l
2 stands for middle.
l
3 stands for high.
l
4 stands for ASAP.
2
Modes
Normal mode.
Level
Super administrator level and administrator level.
Usage Guidelines
You can only roll back the HyperImage with the
Public
type and in
Active
state.
Example
Roll back the HyperImage with the
ID
of
19
. Set
rollback speed
to
high
.
OceanStor: admin> rollbackhyimg -i 19 -l 3
The command has been sent, please wait...
System Response
None.
9.1.15 recreatehyimg
Function
The command
recreatehyimg
is used to recreate a HyperImage.
Format
recreatehyimg
-i
{
HyperImage ID
...}
9 Value-Added Service Management Commands
OceanStor S2600 Storage System
Command Reference
9-16
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.