Parameter
Condition
Requirement
Non-operating ambient
temperature
-40°C to +70°C (-40°F to +158°F)
Storage temperature
(during transportation
and storage with
packages)
-40°C to +70°C (-40°F to +158°F)
Humidity
Operating humidity
10% RH
a
to 90% RH
Non-operating ambient
humidity
5% RH to 95% RH
Maximum humidity
variation
10 %/h
Storage humidity
(during transportation
and storage with
packages)
5% RH to 95% RH
Altitude
Operating altitude of
disks
l
HDDs: -304.8 m to +3048 m (-1000 ft.
to +10000 ft.)
l
SSDs: -305 m to +3048 m (-1000.66 ft.
to +10000 ft.)
Non-operating altitude
of disks
l
HDDs: -305 m to +12192 m (-1000.66
ft. to +40000 ft.)
l
SSDs: -305 m to +12192 m (-1000.66
ft. to +40000 ft.)
a: RH, Relative Humidity
7.2 Vibration and Shock
Vibration and shock requirements must be met so that storage systems can work correctly or
be properly preserved.
lists the vibration and shock requirements of storage systems.
Table 7-2
Vibration and shock requirements of storage systems
Parameter
Requirement
Operating vibration
5 to 350 Hz, PSD: 0.0002 g
2
/Hz, 350 to 500 Hz, -3 dB, 0.3 Grms,
axial direction: 3 axes
OceanStor 2600 V3
Product Description
7 Environmental Requirements
Issue 09 (2019-05-15)
Copyright © Huawei Technologies Co., Ltd.
136