5 Power
Issue ()
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
75
Table 5-24
Introduction to the Power System
Indicat
or
Name
Color
Norm
al
Statu
s
Abnor
mal
Status
Remarks
Input
indicato
r
Green
On
Off
The indicator is on when the input is normal, and
is off when the input is abnormal.
Blink
Overvoltage or undervoltage is input.
The panel switch is Off.
Output
indicato
r
Green
On
Off
The indicator is on when the output is normal,
and is off when the output is abnormal.
Fault
indicato
r
Red
Off
Blink
The indicator is blinking in the following
situations:
The communication is interrupted for 60s or more
than 60s.
The power is input unevenly.
The AC power module is reset remotely.
On
The indicator is blinking in the following
situations:
Protection against overtemperature is performed.
Fans become faulty.
Technical Specifications
Item
Specification
Dimensions (H x D x W)
42mm x 198.5mm x 183.8mm (1.65 in. x 7.81 in. x 7.23
in.)
Weight
2.5 kg (5.51 lb)
Rated AC input voltage
200V-240V/100V-127V(dual-live-wire)
AC input voltage range
180V to 264V
Maximum current
10 A