HUAWEI MU709 Series HSPA+ LGA Module
Hardware Guide
Electrical and Reliability Features
Issue 09 (2017-12-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
61
Item
Test Condition
Standard
Sample size
Results
Thermal
shock
Low temperature:
–40ºC
High temperature: 85ºC
Temperature change
interval: < 20s
Operation mode: no
power
Test duration: 100 cycles;
15 min+15 min/cycle
JESD22-A1
06-B
3 pcs/group
Visual inspection:
ok
Function test: ok
RF specification: ok
Salty fog test
Temperature: 35°C
Density of the NaCl
solution: 5%±1%
Operation mode: no
power, no package
Test duration:
Spraying interval: 8 h
Exposing period after
removing the salty fog
environment: 16 h
JESD22-A1
07-B
3 pcs/group
Visual inspection:
ok
Function test: ok
RF specification: ok
Sine
vibration
Frequency range: 5 Hz to
200 Hz
Acceleration: 1 Grms
Frequency scan rate: 0.5
oct/min
Operation mode: working
with service connected
Test duration: 3 axial
directions. 2 h for each
axial direction.
JESD22-B1
03-B
3 pcs/group
Visual inspection:
ok
Function test: ok
RF specification: ok
Shock test
Half-sine wave shock
Peak acceleration: 30
Grms
Shock duration: 11 ms
Operation mode: working
with service connected
Test duration: 6 axial
directions. 3 shocks for
each axial direction.
JESD-B104
-C
3 pcs/group
Visual inspection:
ok
Function test: ok
RF specification: ok