NOTE
Prerequisite
l
Frequency planning
l
Expected EQ1 and EQ2 values
Level L
amp2_ch
x
of the channel (channelx) whose center frequency is at the AMP2 output
point =
Output power of a single CMC channel
–
EQ1 x (Highest frequency
–
x)/
(Highest frequency
–
Lowest frequency) +
Gain from the DS to the AMP2 input point
(assuming ATT1 = 0)
AMP2 total output power P
amp2_total
= 10 x lgΣ (10
Lamp2_ch
1
/10
, 10
Lamp2_ch
2
/10
, ...
10
Lamp2_ch
n
/10
)
NOTE
l
Maximum downstream frequency: 1218 MHz
l
Minimum downstream frequency: 85 MHz
When the Tx power meets the requirements, ensure that the output power of the AMP2 and
AMP1 amplifiers is not saturated.
Calculation method for the AMP1 total output power P
amp1_total
:
NOTE
Prerequisite
l
Frequency planning
l
Output level on an RF OUT port@1218 MHz
l
Expected EQ1 and EQ2 values
1.
Calculate the level of each channel on the RF OUT port based on the output level on an
RF OUT port@1218 MHz. For example, calculate the level L
ch
x
of the channel whose
center frequency is x MHz as follows: L
ch
x
= (EQ1 + EQ2)/(Highest frequency
–
Lowest frequency) x (x
–
Lowest frequency) + Output level on an RF OUT port@1218
MHz
–
(EQ1 + EQ2)
2.
Level L
amp1_ch
x
of the channel whose center frequency is x MHz on the AMP1 output
point = L
ch
x
–
Gain from the AMP1 output point to the RF OUT point
3.
AMP1 total output power P
amp1_total
= 10 x lgΣ (10
Lamp1_ch
1
/10
, 10
Lamp1_ch
2
/10
, ...
10
Lamp1_ch
n
/10
)
NOTE
l
Maximum downstream frequency: 1218 MHz
l
Minimum downstream frequency: 85 MHz
Calculate P
amp1_total
. Determine whether AMP1 is of the saturated power. If yes, the expected
output power of the RF OUT port is high. To reduce this power, reduce the expected output
power of the RF OUT port.
NOTE
Saturated output power of AMP1 ≈ 72 dBmV
Configuring manual adjustment of the downstream output power
MA5833-BS60
Hardware Commissioning Guide
6 Configuring Intelligent RF Adjustment
Issue 01 (2018-12-12)
Copyright © Huawei Technologies Co., Ltd.
20