background image

M200 Integrated Access Device 
Product Description 

Index 

 

Issue 01 (2008-04-11) 

Huawei Proprietary and Confidential                                     

Copyright © Huawei Technologies Co., Ltd 

i-1 

 

Index 

1

 

10A overcurrent protection, 2-7 

2

 

2-level and 3-line indirect lightning protection at the 
level of 6000 A, 2-7 

A

 

AC filter, 2-7 

D

 

detection of the grounding and the polarity, 2-7 
dimensions of the device, 3-2 
dimensions of the M200, 2-2 
door status sensor, 2-10 

E

 

easy installation and maintenance, 1-8 
ESCM, 1-7 

G

 

GIE4805S power system, 2-6 

H

 

HABM shelf, 3-5 

L

 

lightning protection busbar, 2-6, 2-7 

P

 

power surge protection, 2-7 
prominent security performance, 1-2 

R

 

real-time monitoring, 1-7 

S

 

structure, 2-5 

T

 

temperature and humidity sensor, 2-10 

W

 

weight of the device, 3-3 
 

 

Содержание M200

Страница 1: ...Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd M200 Integrated Access Device V100R017 Product Description Issue 01 Date 2008 04 11 ...

Страница 2: ... reserved No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co Ltd Trademarks and Permissions and other Huawei trademarks are trademarks of Huawei Technologies Co Ltd All other trademarks and trade names mentioned in this document are the property of their respective holders Notice The information in this docu...

Страница 3: ...7 1 5 Compact and Reliable Structure 1 8 2 Structure 2 1 2 1 Appearance 2 2 2 2 Structure 2 5 2 3 Power System 2 6 2 3 1 GIE4805S Power System 2 6 2 3 2 Lightning Protection Busbar 2 7 2 3 3 DC Power Distribution Panel 2 7 2 4 Monitoring System 2 9 2 4 1 ESCM 2 9 2 4 2 Sensors 2 10 2 5 Cable Distribution Unit 2 12 2 5 1 MDF 2 12 2 5 2 ODF 2 13 3 Parameters 3 1 3 1 Dimensions 3 2 3 2 Weight 3 3 3 3...

Страница 4: ......

Страница 5: ...stalled on a wall 1 6 Figure 2 1 Appearance of the M200 cabinet door closed 2 3 Figure 2 2 Appearance of the M200 cabinet door open 2 3 Figure 2 3 Structure of the M200 cabinet 2 5 Figure 2 4 Appearance of the lightning protection busbar 2 7 Figure 2 5 Appearance of the DC power distribution panel 2 8 Figure 2 6 DC power system 2 8 Figure 2 7 Appearance of the ESCM 2 9 Figure 2 8 Appearance of the...

Страница 6: ......

Страница 7: ...vice 2 9 Table 2 4 Parameters of the MDF used in the M200 cabinet 2 12 Table 2 5 Parameters of the ODF used in the M200 cabinet 2 13 Table 3 1 Dimensions of the device 3 2 Table 3 2 Weight of the device 3 3 Table 3 3 Number of the subscriber supported by the M200 cabinet in different configurations 3 4 Table 3 4 System power of the M200 cabinet 3 5 Table 3 5 Environmental parameters for the storag...

Страница 8: ......

Страница 9: ...he M200 cabinet Related Version The following table lists the product version related to this document Product Name Version UA5000 V100R017 Intended Audience The intended audience of this document is Network planning engineers Installation and commissioning engineers Field maintenance engineers Network monitoring engineers System maintenance engineers Data configuration engineers Application devel...

Страница 10: ... in terms of environment structure power system and lighting protection A Acronyms and Abbreviations The acronyms and abbreviations used in this document Conventions Symbol Conventions The following symbols may be found in this document They are defined as follows Symbol Description Indicates a hazard with a high level of risk which if not avoided will result in death or serious injury Indicates a...

Страница 11: ...tems keywords or arguments in square brackets are optional x y Alternative items are grouped in braces and separated by vertical bars One is selected x y Optional alternative items are grouped in square brackets and separated by vertical bars One or none is selected x y Alternative items are grouped in braces and separated by vertical bars A minimum of one or a maximum of all can be selected GUI C...

Страница 12: ...eys should be pressed in turn Mouse Operation Action Description Click Select and release the primary mouse button without moving the pointer Double click Press the primary mouse button twice continuously and quickly without moving the pointer Drag Press and hold the primary mouse button and move the pointer to a certain position Update History Updates between document versions are cumulative Ther...

Страница 13: ...nent security performance to comply with the international safety standards 1 2 Prominent Protection Performance The M200 cabinet features prominent protection performance to meet the requirements of the indoor environment 1 3 Easy Installation The M200 cabinet can be installed on a concrete floor or on a wall 1 4 Prominent Monitoring and Maintainability The structure of the M200 cabinet meets the...

Страница 14: ...The M200 cabinet features prominent security performance to comply with the international safety standards The M200 cabinet features prominent protection performance and anti attack performance The equipment compartment and the cable distribution compartment of the M200 cabinet are equipped with separate doors The single point round lock is used to protect the devices inside the cabinet ...

Страница 15: ...t features prominent performance in mold proofing moisture proofing and anticorrosion Functions of the lightning protection busbar used in the M200 cabinet are 2 level and 3 line indirect lightning protection at the level of 6000 A detection of the grounding and the polarity 10A overcurrent protection AC filter and power surge protection The built in external line protection unit and the service b...

Страница 16: ...04 11 1 3 Easy Installation The M200 cabinet can be installed on a concrete floor or on a wall The M200 cabinet features reasonable design and easy installation The M200 cabinet can be installed on a concrete floor in two ways Figure 1 1 shows the M200 cabinet installed by using the support Figure 1 2 shows the M200 cabinet installed without using the support ...

Страница 17: ...1 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 1 5 Figure 1 1 M200 cabinet installed on a concrete floor by using the support Figure 1 2 M200 cabinet installed on a concrete floor without using the support Figure 1 3 shows the M200 cabinet installed on a wall ...

Страница 18: ...roduct Feature M200 Integrated Access Device Product Description 1 6 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 01 2008 04 11 Figure 1 3 M200 cabinet installed on a wall ...

Страница 19: ...ing and easy maintenance The built in ESCM of the M200 cabinet monitors the environment parameters ambient temperature humidity door status and main distribution frame of the overall system and provides extension monitoring ports The M200 cabinet provides an AC power socket to supply power to other external devices on site The ESCM is optional and you can decide whether to use the ESCM based on yo...

Страница 20: ...n unit environment monitoring device main distribution frame MDF optical distribution frame ODF lightning protection busbar and GIE4805S power system or DC power distribution panel The M200 cabinet can be installed quickly on site to meet the requirements of quick deployment The ventilation design of the M200 cabinet ensures that the cabinet can run reliably when the cabinet is not configured with...

Страница 21: ...ure The components of the M200 cabinet include the power system monitoring device and cable distribution unit 2 3 Power System The power system of the M200 cabinet consists of the GIE4805S power system and the lightning protection busbar AC powered or the power distribution panel DC powered 2 4 Monitoring System The monitoring system of the M200 cabinet consists of the ESCM and the sensor transfer...

Страница 22: ... Ltd Issue 01 2008 04 11 2 1 Appearance This topic provides the appearance of the M200 cabinet when the cabinet door is open and closed The M200 cabinet is made of electrolytic piece The dimensions of the M200 cabinet are 550 mm x 800 mm x 400 mm width x height x depth Figure 2 1 and Figure 2 2 show the appearance of the M200 cabinet ...

Страница 23: ...ion 2 Structure Issue 01 2008 04 11 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 2 3 Figure 2 1 Appearance of the M200 cabinet door closed 250mm 550mm 400mm 800mm 411mm Figure 2 2 Appearance of the M200 cabinet door open ...

Страница 24: ...2 Structure M200 Integrated Access Device Product Description 2 4 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 01 2008 04 11 ...

Страница 25: ...hows the structure of the M200 cabinet Figure 2 3 Structure of the M200 cabinet HABM ODF MDF Metro100 optional GIE4805S or DC power distribution panel ESCM optional Lightning protection busbar Temperature and humidity sensor optional The M200 cabinet can be AC powered or DC powered When the M200 cabinet is DC powered the M200 cabinet uses the DC power distribution panel When the M200 cabinet is AC...

Страница 26: ...wered M200 cabinet uses the DC power distribution panel to distribute the power 2 3 1 GIE4805S Power System The M200 cabinet uses the GIE4805S power system to convert 220 VAC into 48 VDC and then distribute the power Table 2 1 describes the configuration of the GIE4805S power system Table 2 1 Configuration of the GIE4805S power system Component Quantity GIE270 54A rectifier unit 2 Monitoring unit ...

Страница 27: ...des the related technical specifications of the lightning protection busbar The M200 cabinet is equipped with a lightning protection busbar and need not be configured with an extra maintenance socket Figure 2 4 shows the appearance of the lightning protection busbar Figure 2 4 Appearance of the lightning protection busbar Functions of the lightning protection busbar are as follows 2 level and 3 li...

Страница 28: ...e 2 5 Appearance of the DC power distribution panel The DC power supply is connected to the power distribution panel of the device and the power distribution panel distributes the power to each component of the device Figure 2 6 shows the DC power system Figure 2 6 DC power system Transmission unit Terminal block Terminal block DC MCB 48V NEG 48V RTN HABM Mini ESC ...

Страница 29: ...ut the functions of the sensors 2 4 1 ESCM The M200 cabinet uses the ESCM to monitor the device environment The ESCM is an environment monitoring unit EMU that integrates the environment monitoring board terminal block and DIP switch The ESCM monitors the environment parameters of the entire device such as door status MDF temperature humidity and lightning arrester and provides the extended monito...

Страница 30: ...h consists of two built in parts The spring clips of the door status switch attract each other due to electromagnetic interaction The door status switch monitors the status of the cabinet door and outputs the dry contact output signals that have no polarity Figure 2 8 shows the appearance of the door status sensor Figure 2 8 Appearance of the door status sensor Temperature and Humidity Sensor The ...

Страница 31: ...grated Access Device Product Description 2 Structure Issue 01 2008 04 11 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd 2 11 Figure 2 9 Appearance of the temperature and humidity sensor ...

Страница 32: ...ide terminal blocks are also used for tests and open circuits The 10 pair cable side terminal blocks are installed to connect the external cables of the MDF and the jumper cables The protective unit installed in the cable side terminal block provides the overvoltage protection and generates alarms The harness which consists of a connector subscriber cables and a terminal block provides connections...

Страница 33: ...communication devices The ODF can perform the following Fasten and protect optical fibers Protect the cores of the peeled optical fibers Distribute optical fibers Adjust optical fibers Store optical fibers Figure 2 10 shows the appearance of the ODF used in the M200 cabinet Figure 2 10 Appearance of the ODF used in the M200 cabinet Table 2 5 provides the parameters of the ODF used in the M200 cabi...

Страница 34: ......

Страница 35: ...the cabinet 3 1 Dimensions This topic provides the dimensions of the cabinet and the shelf 3 2 Weight This topic provides the weight of the M200 cabinet 3 3 System Configuration This topic provides the information about the number of subscribers supported by the service shelf of Huawei 3 4 System Power This topic provides the system power of the M200 cabinet 3 5 Environmental Parameters This topic...

Страница 36: ...ht Huawei Technologies Co Ltd Issue 01 2008 04 11 3 1 Dimensions This topic provides the dimensions of the cabinet and the shelf Table 3 1 provides the dimensions of the device Table 3 1 Dimensions of the device Item Dimensions W x D x H M200 cabinet 550 mm x 400 mm x 800 mm HABM shelf 436 mm x 219 mm x 370 mm ...

Страница 37: ...ry and Confidential Copyright Huawei Technologies Co Ltd 3 3 3 2 Weight This topic provides the weight of the M200 cabinet Table 3 2 provides the weight of the device Table 3 2 Weight of the device Item Weight M200 cabinet fully loaded 50 kg M200 cabinet empty 22 5 kg HABM shelf fully loaded 15 5 kg ...

Страница 38: ...ormation about the number of subscribers supported by the service shelf of Huawei Table 3 3 provides the information about the number of subscribers supported by the M200 cabinet in different configurations Table 3 3 Number of the subscriber supported by the M200 cabinet in different configurations Configuration Subscriber Capacity 6 A32 boards 192 POTS subscribers 6 CSRB boards 192 POTS ADSL ADSL...

Страница 39: ...4 System Power This topic provides the system power of the M200 cabinet Table 3 4 provides the system power of the M200 cabinet Table 3 4 System power of the M200 cabinet Configuration Maximum Power HABM shelf 359 W Metro100 17 W M200 cabinet AC powered 1092 W In the AC powered cabinet the rated power for the standard input of the AC maintenance socket is 660 W ...

Страница 40: ...orage transportation and running of the M200 cabinet Table 3 5 Environmental parameters for the storage transportation and running of the M200 cabinet Environment Item Value Temperature 25 C to 50 C Relative humidity 5 to 99 Storage Air pressure 70 kPa to 106 kPa Temperature 45 C to 70 C Relative humidity without a lot of variation in temperature 95 45 C Relative humidity with a lot of variation i...

Страница 41: ...ss 3 3 Not temperature controlled locations Transpor tation environ ment ETSI 300 019 1 2 Environmental conditions and environmental test for telecommunications equipment Part 1 2 Classification of environmental conditions Transportation Class 2 3 Public transportation Safety IEC 60950 1 Safety of information of technology equipment Necessary Protectio n IEC 529 Degrees of protection provided by e...

Страница 42: ...rietary and Confidential Copyright Huawei Technologies Co Ltd Issue 01 2008 04 11 Item Standards Compliance Class centers and groundin g IEC 61643 Performance requirement for surge protective device connected to low voltage distribution systems of telecommunication stations sites Necessary ...

Страница 43: ... line ADSL2 Asymmetrical digital subscriber line two plus D DC Direct current E EMU Environment monitor unit EN End node ETS European Telecommunication Standards ETSI European Telecommunications Standards Institute F FC Fiber channel I IDC Internet data center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IP Internet Protocol ITU T Internation...

Страница 44: ... Product Description A 2 Huawei Proprietary and Confidential Copyright Huawei Technologies Co Ltd Issue 01 2008 04 11 M MDF Main distribution frame O ODF Optical distribution frame P POTS Plain Old Telephone Service PSTN Public switched telephone network ...

Страница 45: ...6000 A 2 7 A AC filter 2 7 D detection of the grounding and the polarity 2 7 dimensions of the device 3 2 dimensions of the M200 2 2 door status sensor 2 10 E easy installation and maintenance 1 8 ESCM 1 7 G GIE4805S power system 2 6 H HABM shelf 3 5 L lightning protection busbar 2 6 2 7 P power surge protection 2 7 prominent security performance 1 2 R real time monitoring 1 7 S structure 2 5 T te...