Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Blinking at 4 Hz
Off
Data is being read or written normally,
or data on the primary drive is being
rebuilt.
Steady on
Blinking at 1 Hz
The drive is being located.
Blinking at 1 Hz
Blinking at 1 Hz
The data on the secondary drive is
being rebuilt.
Off
Steady on
A member drive in the RAID array is
removed.
Steady on
Steady on
The drive is faulty.
NVMe Drive Indicators
Figure 5-23 NVMe drive indicators
Table 5-10 Description of NVMe drive indicators (only orderly hot swap
supported)
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The NVMe drive cannot be detected.
Steady on
Off
The NVMe drive is working properly.
Blinking at 2 Hz
Off
Data is being read from or written to
the NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located or
hot-swapped.
Off
Blinking at 0.5 Hz
The hot removal process is complete,
and the NVMe drive is removable.
Steady on/Off
Steady on
The NVMe drive is faulty.
Huawei FusionServer Pro 2488H V5 Server
Technical White Paper
5 Hardware Description
Issue 03 (2020-04-20)
Copyright © Huawei Technologies Co., Ltd.
34