background image

D

DC

direct current

DDR3

Double Data Rate 3

DDR4

Double Data Rate 4

DDDC

double device data correction

DEMT

Dynamic Energy Management Technology

DIMM

dual in-line memory module

DRAM

dynamic random-access memory

DVD

digital video disc

 

E

ECC

error checking and correcting

ECMA

European Computer Manufacturer Association

EDB

Execute Disable Bit

EN

European Efficiency

ERP

enterprise resource planning

ETS

European Telecommunication Standards

 

C.2 F-J

F

FB-DIMM

Fully Buffered DIMM

FC

Fiber Channel

FCC

Federal Communications Commission

FCoE

Fibre Channel over Ethernet

FTP

File Transfer Protocol

 

G

GE

Gigabit Ethernet

Huawei FusionServer Pro 2298 V5 Server

Technical White Paper

C Acronyms and Abbreviations

Issue 05 (2020-09-03)

Copyright © Huawei Technologies Co., Ltd.

72

Содержание FusionServer Pro 2298 V5

Страница 1: ...Huawei FusionServer Pro 2298 V5 Server V100R005 Technical White Paper Issue 05 Date 2020 09 03 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ...cribed in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the prep...

Страница 3: ...k which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance dete...

Страница 4: ...tion 05 2020 09 03 This issue is the fifth official release 04 2020 07 31 This issue is the fourth official release 03 2020 06 05 This issue is the third official release 02 2020 04 20 This issue is the second official release 01 2019 12 31 This issue is the first official release Huawei FusionServer Pro 2298 V5 Server Technical White Paper About This Document Issue 05 2020 09 03 Copyright Huawei ...

Страница 5: ...ifier 18 5 4 2 Memory Subsystem Architecture 19 5 4 3 Memory Compatibility 20 5 4 4 Memory Installation Guidelines 22 5 4 5 Memory Installation Positions 22 5 4 6 Memory Protection Technologies 24 5 5 Storage 24 5 5 1 Drive Configurations 25 5 5 2 Drive Numbering 25 5 5 3 Drive Indicators 28 5 5 4 RAID Controller Card 31 5 6 Network 31 5 6 1 LOMs 31 5 6 2 OCP 2 0 Mezzanine Cards 34 5 7 I O Expansi...

Страница 6: ... 8 Safety Instructions 52 8 1 Safety Instructions 52 8 2 Maintenance and Warranty 55 9 System Management 56 10 Certifications 58 A Appendix 59 A 1 Product SN 59 A 2 Operating Temperature Limitations 60 A 3 RAS Features 60 A 4 Sensor List 62 B Glossary 68 B 1 A E 68 B 2 F J 69 B 3 K O 69 B 4 P T 69 B 5 U Z 70 C Acronyms and Abbreviations 71 C 1 A E 71 C 2 F J 72 C 3 K O 73 C 4 P T 74 C 5 U Z 76 Hua...

Страница 7: ...re defined storage video backup and archiving and other storage intensive cold storage scenarios It delivers unmatched flexibility and expandability of local storage reduced storage costs as well as high computing performance The 2298 V5 features ultra high density superb performance easy O M and high expandability Figure 1 1 2298 V5 Huawei FusionServer Pro 2298 V5 Server Technical White Paper 1 O...

Страница 8: ... Intel VT allows operating system OS vendors to better use hardware to address virtualization workloads Intel Advanced Vector Extensions 512 Intel AVX 512 significantly accelerates floating point performance for computing intensive applications The Cascade Lake processors support Intel Deep Learning Boost vector neural network instructions VNNI to improve the performance of deep learning applicati...

Страница 9: ...ice upgrades are available Huawei provides a three year warranty for parts replacement and repair for the servers used outside China Huawei provides a 9 hour a day 5 day a week support program Service requests will be handled the next business day Huawei delivers the repaired or new parts within 45 calendar days after receiving the defective parts Manageability and Security The built in iBMC monit...

Страница 10: ...r improved power supply efficiency Efficient voltage regulator down VRD power supplies for boards minimize the energy loss from DC DC power conversion Area based Proportional Integral Derivative PID intelligent fan speed adjustment and intelligent CPU frequency scaling optimize heat dissipation and reduce overall system power consumption The improved thermal design with energy efficient fans ensur...

Страница 11: ...6 Chassis 7 Air duct 1 8 Upper drive drawer 9 Lower drive drawer 10 Fan module bracket 11 Fan modules 12 Air duct 2 13 Heat sinks 14 Processors 15 DIMMs 16 TPM TCM 17 Mainboard 18 OCP 2 0 mezzanine card Huawei FusionServer Pro 2298 V5 Server Technical White Paper 3 Physical Structure Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 5 ...

Страница 12: ...one PCIe 3 0 x8 OCP 2 0 mezzanine card CPU 2 is connected to two half height half length HHHL PCIe 3 0 x16 cards The server supports 24 front 3 5 inch SAS SATA drives directly connected to a 24 port PCIe SAS HBA card The server supports four rear 2 5 inch SAS SATA NVMe drives that can be directly connected to the following signal sources PCIe RAID controller card when SAS SATA drives are configure...

Страница 13: ...GE electrical LOM ports Two SATA or PCIe ports for M 2 SSDs The server uses Hi1710 management chip and supports a video graphic array VGA port a management network port and a debug serial port Huawei FusionServer Pro 2298 V5 Server Technical White Paper 4 Logical Structure Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 7 ...

Страница 14: ...mory 5 5 Storage 5 6 Network 5 7 I O Expansion 5 8 PSUs 5 9 Fans 5 10 Boards 5 1 Front Panel 5 1 1 Appearance Figure 5 1 Front view Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 8 ...

Страница 15: ...lth status indicator 3 10GE optical port LOM port 1 connection status indicator 4 GE electrical port LOM port 3 connection status indicator 5 UID button indicator 6 Non Maskable Interrupt NMI button 7 10GE optical port LOM port 2 connection status indicator 8 GE electrical port LOM port 4 connection status indicator 9 Status indicators of the drives in the front drawers Huawei FusionServer Pro 229...

Страница 16: ...e When the power indicator is steady green you can press this button to power on the device UID button indicator The UID button indicator helps identify and locate a device UID indicator Off The device is not being located Blinking blue The device has been located and is distinguished from other devices that have also been located Steady blue The device is being located UID button You can turn on ...

Страница 17: ...gram Otherwise the OS may crash Exercise caution when pressing this button LOM port connection status indicator Each indicator shows the connection status of an Ethernet LOM port Off The network port is not in use or has failed Steady green The network port is properly connected NOTE The indicators correspond to two 10GE and two GE network ports on the mainboard The LOM has a standby power supply ...

Страница 18: ...a USB device NOTICE Before connecting an external USB device check that the USB device functions properly The server may operate abnormally if an abnormal USB device is connected VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM 5 2 Rear Panel Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technolog...

Страница 19: ...OM 11 Optional OCP 2 0 mezzanine card NOTE For details about the LOM and OCP 2 0 mezzanine card see 5 6 Network The preceding figure is for reference only 5 2 2 Indicators Indicator Positions Figure 5 5 Indicators on the rear panel Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 13 ...

Страница 20: ...erver is standby The input is overvoltage or undervoltage The PSU is in deep hibernation mode Blinking green at 4 Hz The firmware is being upgraded online Steady green The power input and output are normal Steady orange The input is normal but no power output is supplied NOTE The possible causes of no power output are as follows Power supply overtemperature protection Power output overcurrent or s...

Страница 21: ...work port Off The network port is not connected Steady green The network port is properly connected Data transmission status indicator for the management network port Off No data is being transmitted Blinking yellow Data is being transmitted LOM indicators For details see 5 6 1 LOMs OCP 2 0 mezzanine card indicators For details see 5 6 2 OCP 2 0 Mezzanine Cards 5 2 3 Ports Port Positions Figure 5 ...

Страница 22: ... Status cannot be set to Active Standby on the iBMC WebUI Serial port RJ45 1 Default operating system serial port used for debugging You can also set it as the iBMC serial port by using the iBMC command NOTE The port uses 3 wire serial communication interface and the default baud rate is 115 200 bit s Management network port 1000BASE T 1 Used for server management NOTE The management network port ...

Страница 23: ...one or two processors If only one processor is required install it in socket CPU1 The same model of processors must be used in a server Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used NOTICE According to Intel s statement the processors in overclocking mode may cause instantaneous thermal throttling on certain...

Страница 24: ...You can determine the memory module properties based on the label attached to the memory module Figure 5 8 Memory identifier Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 18 ...

Страница 25: ...d 2133 MT S 2400 MT S 2666 MT S 2933 MT S 6 Column Access Strobe CAS latency P 15 T 17 7 DIMM type R RDIMM L LRDIMM 5 4 2 Memory Subsystem Architecture The 2298 V5 provides 12 memory slots Each processor integrates six memory channels Table 5 5 Memory channels CPU Memory Channel Memory Slot CPU 1 A DIMM000 A B DIMM010 B C DIMM020 C D DIMM030 D E DIMM040 E Huawei FusionServer Pro 2298 V5 Server Tec...

Страница 26: ...ot be used together Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used The memory can be used with Intel Xeon Scalable Skylake and Cascade Lake processors The maximum memory capacity supported varies depending on the processor model Skylake processors M processors 1 5 TB socket Other processors 768 GB socket Casc...

Страница 27: ... DIMMs supported by each channel Number of ranks supported by each memory channel Number of ranks supported by each DIMM Table 5 6 DDR4 memory specifications Parameter Specifications Maximum capacity per DDR4 DIMM GB 16 16 32 32 64 Rated speed MT s 2666 2933 2666 2933 2933 Rank Dual rank Dual rank Dual rank Dual rank Dual rank Operating voltage V 1 2 1 2 1 2 1 2 1 2 Maximum number of DDR4 DIMMs in...

Страница 28: ...ating mode Memory sparing mode Comply with the general installation guidelines Each memory channel must have a valid online spare configuration The channels can have different online spare configurations Each populated channel must have a spare rank Memory mirroring mode Comply with the general installation guidelines Each processor supports two integrated memory controllers IMCs At least two chan...

Страница 29: ...ory slots corresponding to CPU 1 Figure 5 9 Memory slots Figure 5 10 DDR4 memory installation guidelines 1 processor Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 23 ...

Страница 30: ...DC SDDC 1 Rank sparing mode Static virtual lockstep Faulty DIMM isolation Memory thermal throttling Memory address parity protection Memory demand patrol scrubbing Device tagging Data scrambling Adaptive double device data correction ADDDC ADDDC 1 5 5 Storage Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd...

Страница 31: ...as rear drives a PCIe RAID controller card can be configured to manage the rear drives c The SATA drives used as rear drives can be directly connected to the PCH d The NVMe drives used as rear drives can be directly connected to the CPU e The M 2 SSDs come in two sizes 2242 and 2280 and supports SATA and PCIe interfaces Contact your local Huawei sales representative or use the Computing Product Co...

Страница 32: ...umbering Rear drives Figure 5 13 Drive numbering Built in drives M 2 SSD 0 1 Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 26 ...

Страница 33: ...Figure 5 14 Drive numbering Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 27 ...

Страница 34: ...ing located Off The drive is not in position Table 5 9 Description of status indicators of the front drive drawer Activity Indicator Green Fault Indicator Yellow Description Blinking at 0 5 Hz Off The RAID group is being rebuilt or the member drive is being replaced Blinking at 1 Hz Off The drive is being identified or to be deleted Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Ha...

Страница 35: ...position SAS SATA Drive Indicators Figure 5 16 SAS SATA drive indicators Table 5 10 Description of SAS SATA drive indicators Activity Indicator Green Fault Indicator Yellow Description Steady on Off The drive is in position Blinking at 4 Hz Off Data is being read or written normally or data on the primary drive is being rebuilt Steady on Blinking at 1 Hz The drive is being located Blinking at 1 Hz...

Страница 36: ...e NVMe drive is working properly Blinking at 2 Hz Off Data is being read from or written to the NVMe SSD Off Blinking at 2 Hz The NVMe drive is being located Off Blinking at 8 Hz The data on the secondary NVMe drive is being rebuilt Steady on Off Steady on The NVMe drive is faulty If the VMD function is disabled NVMe drives support only orderly hot swap Table 5 12 NVMe drive indicators VMD disable...

Страница 37: ...ing If SAS SATA drives are used as rear drives a RAID controller card can be configured to manage the rear drives Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used For details about the RAID controller card see Huawei V5 Server RAID Controller Card User Guide 5 6 Network 5 6 1 LOMs LOMs provide network expansion...

Страница 38: ...rts do not support forced rates The electrical LOM ports cannot be connected to power over Ethernet PoE devices such as a switch with PoE enabled Connecting a LOM port to a PoE device may cause link communication failure or even damage the NIC The electrical LOM ports do not support SR IOV Forcibly powering off a server will cause intermittent NC SI disconnection and disable the Wake on LAN WOL fu...

Страница 39: ...ted Steady green The network port is properly connected Data transmission rate indicator for a 10GE optical port Off The network port is not connected Steady green The data transmission rate is 10 Gbit s Steady yellow The data transmission rate is lower than 10 Gbit s Data transmission status indicator for a GE electrical port Off The network port is not connected Steady yellow The network port is...

Страница 40: ...x 25GE optical ports Figure 5 20 OCP 2 0 mezzanine card indicators 2 x 25GE optical ports 1 Connection status indicator Data transmission status indicator for a 25GE optical port 2 Data transmission rate indicator for a 25GE optical port Indicator Description Table 5 16 OCP 2 0 mezzanine card indicators Indicator Description Connection status indicator Data transmission status indicator for a 25GE...

Страница 41: ... for standard PCIe cards are supported Contact your local Huawei sales representative or use the Computing Product Compatibility Checker to determine the components to be used 5 7 2 PCIe Slots PCIe Slots Figure 5 21 PCIe slots Slots 1 and 2 are provided by the PCIe riser module By default slot 1 is configured with a 24 port SAS HBA card Slots 3 and 4 are provided by the mainboard Huawei FusionServ...

Страница 42: ...vailable Table 5 17 PCIe slot description PCIe Slot CPU PCIe Stand ards Conne ctor Width Bus Width Port No Root Port B D F Device B D F Slot Size LOM CPU1 PCIe 3 0 x8 x8 Port1C 85 02 0 89 00 0 Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 36 ...

Страница 43: ...dicates the B D F displayed on the OS of an onboard or extended PCIe device The PCIe x16 slots are backward compatible with PCIe x8 PCIe x4 and PCIe x1 cards The PCIe cards are not forward compatible That is the PCIe slot width cannot be smaller than the PCIe card link width The full height half length FHHL PCIe slots are backward compatible with half height half length HHHL PCIe cards All slots s...

Страница 44: ...Us When the input voltage is from 100 V AC to 132 V AC the output power drops to 1000 W Two 1500 W AC Platinum PSUs can serve as 1700 W PSUs Figure 5 23 PSU positions 5 9 Fans The server supports five fan modules The fan modules are hot swappable The server tolerates failure of a single fan The fan speed can be adjusted The same model of fan modules must be used in a server Huawei FusionServer Pro...

Страница 45: ...Figure 5 24 Fan module positions 5 10 Boards Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 39 ...

Страница 46: ...8 J9 7 10GE optical port J132 8 10GE optical port J131 9 mini SAS HD connector MINIHD PORTA J86 10 USB 3 0 port USB3 0 CONN J169 11 I2C management network port I2C J10 a 12 USB 3 0 port INNER USB3 0 J173 13 OCP 2 0 mezzanine card slot OCP CARD J5 14 Right mounting ear connector REAR BOARD J186 Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 C...

Страница 47: ...ting ear connector LEAR BOARD J167 25 Fan 1 port FAN0 J105 26 Lower drive drawer management cable connector HDD BP CONN1 J162 27 Mainboard power connector PWR IN1 J185 28 Mainboard power connector PWR IN0 J184 29 PSU management connector J182 30 RTC battery CMOS BATTY U4042 31 Onboard PCIe slot J179 32 Onboard PCIe slot J180 33 PCIe standard card NC SI port NCSI CONN J99 34 VROC key port SOFT RAID...

Страница 48: ...ector J1 3 Slimline connector PORT A 4 Drive identification indicator 5 Indicator signal cable connector J1701 6 Slimline connector PORT B 7 Power connector J2 Rear Drive Backplane Figure 5 27 Rear drive backplane BOM 03024BPV Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 42 ...

Страница 49: ... J2 3 Slimline A connector SLIMLINE A J8 4 Slimline B connector SLIMLINE B J9 5 Backplane signal cable connector HDD BP J23 Huawei FusionServer Pro 2298 V5 Server Technical White Paper 5 Hardware Description Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 43 ...

Страница 50: ...y controller and six memory channels Built in PCIe controller supporting PCIe 3 0 and 48 lanes per processor Two UPI buses between processors providing up to 10 4 GT s transmission per channel Up to 28 cores 2 7 GHz Max 3 8 GHz four cores Min 1 375 MB L3 cache per core Max 205 W TDP NOTE The preceding information is for reference only Use the Computing Product Compatibility Checker to obtain speci...

Страница 51: ... different types RDIMM and LRDIMM and specifications capacity bit width rank and height cannot be used together NOTE The preceding information is for reference only Use the Computing Product Compatibility Checker to obtain specific information Huawei FusionServer Pro 2298 V5 Server Technical White Paper 6 Product Specifications Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 45 ...

Страница 52: ...s not recommended for write intensive service software due to poor endurance Do not use the M 2 SSD as the cache Supports hot swap of SAS SATA NVMe drives NOTE The NVMe drives support Surprise hot swap if the VMD function is enabled and the latest Intel VMD driver is installed Orderly hot swap if the VMD function is disabled Supports a variety of RAID controller cards Use the Computing Product Com...

Страница 53: ...d and four for standard PCIe cards For details see 5 7 2 PCIe Slots and 5 7 3 PCIe Slot Description NOTE The preceding information is for reference only Use the Computing Product Compatibility Checker to obtain specific information Ports Supports a variety of ports Ports on the front panel Two USB 3 0 ports One DB15 VGA port Ports on the rear panel Two USB 3 0 ports One DB15 VGA port One RJ45 seri...

Страница 54: ...sword Administrator password TCM only in China TPM Secure boot 6 2 Environmental Specifications Table 6 2 Environmental specifications Category Specifications Temperature Operating temperature 5 C to 35 C 41 F to 95 F ASHRAE Class A2 compliant Storage temperature 72 hours 40 C to 65 C 40 F to 149 F Long term storage temperature 72 hours 21 C to 27 C 69 8 F to 80 6 F Maximum temperature change rate...

Страница 55: ...ent meets the requirements of ISO 14664 1 Class 8 There is no explosive conductive magnetic or corrosive dust in the equipment room NOTE It is recommended that the particulate pollution in the equipment room be monitored by a professional agency Acoustic noise The declared A weighted sound power levels LWAd and declared average bystander position A weighted sound pressure levels LpAm listed are me...

Страница 56: ... distance of 543 5 mm to 848 5 mm 21 40 in to 33 41 in between the front and rear mounting bars Weight in full configuration Maximum net weight Server with 24 x 3 5 drives 50 kg 110 25 lb Full configuration 24 x 3 5 front drives 4 x 2 5 rear drives 2 x M 2 SSDs Packaging materials 5 kg 11 03 lb Power consumption The power consumption parameters vary with hardware configurations including the confi...

Страница 57: ...ic software and hardware may cause performance inconsistency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact Huawei sales personnel to apply for POC tests in the pre sales phase to determine detailed software and hardware configurations If the customer has requirements on hardware performance consist...

Страница 58: ...g a forklift Take protective measures if a Class A product is used in residential areas as it is likely to cause radio interference Personal Safety Only personnel certified or authorized by Huawei are allowed to install the hardware Stop any operation that may cause personal injury or equipment damage report the problem to a project supervisor immediately and take protective measures Do not operat...

Страница 59: ...ure 8 2 Conductive objects to be removed Figure 8 3 shows how to wear an ESD wrist strap a Secure the ESD wrist strap around your wrist b Fasten the strap buckle and ensure that the ESD wrist strap is in contact with your skin c Insert the ground terminal attached to the ESD wrist strap into the jack on the grounded rack or chassis Huawei FusionServer Pro 2298 V5 Server Technical White Paper 8 Saf...

Страница 60: ...he handles of the installed modules such as the PSUs fan modules drives and the mainboard Handle the equipment with care Exercise caution when using tools that could cause personal injury If the device is configured with active and standby PSUs connect power cables of active and standby PSUs to different power distribution units PDUs to ensure reliable system operating Properly ground a device bef...

Страница 61: ...y a number of organizations Table 8 1 Maximum weight one person is permitted to carry Organization Weight kg lb European Committee for Standardization CEN 25 55 13 International Organization for Standardization ISO 25 55 13 National Institute for Occupational Safety and Health NIOSH 23 50 72 Health and Safety Executive HSE 25 55 13 General Administration of Quality Supervision Inspection and Quara...

Страница 62: ...and text console redirection Remote virtual media IPMI SNMP Common information model CIM Redfish Browser based login Specifications Table 9 1 iBMC specifications Feature Description Management interface Integrates with any standard management system through the following interfaces or protocols IPMI CLI HTTPS SNMP Redfish Fault detection Detects and accurately locates faults in hardware for exampl...

Страница 63: ...erations Fault reproduction Reproduces faults to help diagnose them quickly Screen snapshots and screen videos Allows users to view screenshots and videos without login facilitating routine preventive maintenance inspection PMI Black Box Allows users to enable or disable the black box function and download black box data DNS LDAP Supports domain management and directory services significantly simp...

Страница 64: ...egion Certification Standards China CCC GB4943 1 2011 GB9254 2008 Class A GB17625 1 2012 Huawei FusionServer Pro 2298 V5 Server Technical White Paper 10 Certifications Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 58 ...

Страница 65: ...ple Table A 1 SN description Callout No Description 1 SN ID two characters which is 21 2 Material identification code 8 characters that is the processing code 3 Vendor code two characters 10 indicates Huawei and other values indicate outsourcing vendors Huawei FusionServer Pro 2298 V5 Server Technical White Paper A Appendix Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 59 ...

Страница 66: ...indicates RoHS compliant 7 Internal model that is product name A 2 Operating Temperature Limitations Table A 2 Operating temperature limitations Configuration Max 30 C 86 F Max 35 C 95 F 24 x 3 5 drive configuration All options supported All options supported A 3 RAS Features The server supports a variety of Reliability Availability and Serviceability RAS features You can configure these features ...

Страница 67: ...error possibility to improve the reliability of data streams in the memory and the capability to detect address errors PCIe PCIe Advanced Error Reporting Improves server serviceability UPI Intel UPI Link Level Retry Provides a retry mechanism upon errors to improve UPI reliability Intel UPI Protocol Protection via CRC Provides cyclic redundancy check CRC protection for UPI packets to improve syste...

Страница 68: ...orm Environment Control Interface PECI If a fatal error occurs in the system the out of band system collects onsite data to facilitate fault analysis and locating and improve system serviceability BIOS Abstraction Layer for Error Handling The BIOS processes errors and reports the error information to the OS and the server in compliance with specifications to improve system serviceability BIOS base...

Страница 69: ...s the CPU number The value is 1 or 2 CPUN MEM Temp CPU DIMM temperature DIMMs of CPUN N indicates the CPU number The value is 1 or 2 SYS 3 3V Mainboard 3 3 V voltage Mainboard SYS 5V Mainboard 5 0 V voltage Mainboard SYS 12V_1 Mainboard 12 0 V voltage Mainboard SYS 12V_2 Mainboard 12 0 V voltage Mainboard CPUN VCore 1 8 V CPU voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN DD...

Страница 70: ...voltage Front drive backplane N indicates the backplane number The value is 1 or 2 HDD BPN 5V Drive backplane 5 0 V voltage Front drive backplane N indicates the backplane number The value is 1 or 2 HDD BPN 12V Drive backplane 12 0 V voltage Front drive backplane N indicates the backplane number The value is 1 or 2 CPUN VCCP CPU VCCP voltage Mainboard CPUN DDR VPP1 CPU DDR voltage Mainboard CPUN D...

Страница 71: ...lue is 1 or 2 CPUN Prochot CPU Prochot CPUN N indicates the CPU number The value is 1 or 2 System Error System suspension or restart Check the background logs Mainboard CPUN Status CPU status CPUN N indicates the CPU number The value is 1 or 2 CPUN Memory CPU memory status DIMMs of CPUN N indicates the CPU number The value is 1 or 2 FANN Status Fan status Fan moduleN N indicates the fan module num...

Страница 72: ...er capping status Mainboard HDD Backplane Entity presence Drive backplane HDD BP Status Drive backplane health status Drive backplane Riser1 Card Entity presence Riser card SAS Cable Entity presence SAS cable on the mainboard FANN Presence Fan presence Fan moduleN N indicates the fan module number The value ranges from 1 to 5 RAID Presence RAID controller card presence RAID controller card PS Redu...

Страница 73: ...ard temperature RAID controller card RAID Status RAID controller card health status RAID controller card RAID PCIE ERR RAID controller card fault diagnosis health status RAID controller card IB TEMP IB adapter temperature IB adapter RAID Card BBU RAID controller card BBU BBU supercapacitor of RAID controller card PS Inlet Temp PSU air inlet temperature PSUs OCP1 OP Temp OCP 2 0 mezzanine card opti...

Страница 74: ...ge the objects E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox Corporation by partnering with Intel and DEC Ethernet uses the Carrier Sense Multiple Access Collision Detection CSMA CD access method and allows data transfer over various cables at 10 Mbit s The Ethernet...

Страница 75: ...erver It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility EMC Peripheral Component Interconnect Express PCIe A computer bus PCI which uses the existing PCI programming concepts and communication standards but builds a faster serial communication system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI syst...

Страница 76: ...pecial computer that provides services for clients over a network system event log SEL A non volatile area and interfaces used to store system events for later fault diagnosis and system recovery B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet or chassis 1 U 44 45 mm UltraPath Interconnect UPI A point to point processor interco...

Страница 77: ... Vector Extensions B BBU backup battery unit BIOS Basic Input Output System BMC baseboard management controller C CD calendar day CE Conformite Europeenne CIM Common Information Model CLI command line interface Huawei FusionServer Pro 2298 V5 Server Technical White Paper C Acronyms and Abbreviations Issue 05 2020 09 03 Copyright Huawei Technologies Co Ltd 71 ...

Страница 78: ...an Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber Channel FCC Federal Communications Commission FCoE Fibre Channel over Ethernet FTP File Transfer Protocol G GE Gigabit Ethernet Huawei FusionServer Pro 2298 V5 Server Technical White Paper C Acro...

Страница 79: ...ternet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations per second IP Internet Protocol IPC intelligent power capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface C 3 K O K KVM keyboard video and mouse Huawei FusionServer Pr...

Страница 80: ... Controller Sideband Interface C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK power OK PWM pulse width modulation PXE Preboot Execution Environment Q QPI Quick Path Interconnect Huawei FusionServer Pro 2298 V5 Server Technical White Paper C Acronyms and Abbreviations Issue 05 2020 09 03 Copyright Huawei Technol...

Страница 81: ... single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SOL serial over LAN SONCAP Standards Organization of Nigeria Conformity Assessment Program SSD solid state drive SSE Streaming SIMD Extensions T TACH tachometer signal TBT Turbo Boos...

Страница 82: ...e Interface UID unit identification light UL Underwriter Laboratories Inc USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by Information Technology Equipment VGA Video Graphics Array VLAN virtual local area network VRD voltage regulator down W WEEE waste electrical and electronic equipment WSMAN Web Service Management Huawei FusionServer Pro 2298 V5 Server Technical Whit...

Отзывы: