Activity
Indicator
(Green)
Fault Indicator
(Yellow)
Description
Steady on
Off
The NVMe drive is working properly.
Blinking at 2 Hz
Off
Data is being read from or written
to the NVMe drive.
Off
Blinking at 2 Hz
The NVMe drive is being located or
hot-swapped.
Off
Blinking at 0.5
Hz
The hot removal process is
complete, and the NVMe drive is
removable.
Steady on/Off
Steady on
The NVMe drive is faulty.
5.5.4 RAID Controller Card
The RAID controller card supports RAID configuration, RAID level migration, and
drive roaming.
●
If SAS/SATA drives are used as rear drives, a RAID controller card can be
configured to manage the rear drives.
●
Contact your local Huawei sales representative or use the
to determine the components to be used.
●
For details about the RAID controller card, see
.
5.6 Network
5.6.1 LOMs
LOMs provide network expansion capabilities.
Table 5-13 LOMs supported by the 2298 V5
NIC Type Chip
Model
Port
Type
Number
of Ports
NC-SI
WOL
PXE
LOM
X722
10GE
optical
port
2
√
√
√
GE
electrical
port
2
√
√
√
Huawei FusionServer Pro 2298 V5 Server
Technical White Paper
5 Hardware Description
Issue 05 (2020-09-03)
Copyright © Huawei Technologies Co., Ltd.
31