background image

Category

Description

Installation space

● Requirements for cabinet installation:

Cabinet compliant with the International

Electrotechnical Commission (IEC) 297 standard
– Cabinet width: 482.6 mm (19 in.)
– Cabinet depth ≥ 1000 mm (39.37 in.)

● Requirements for guide rail installation:

– L-shaped guide rails: apply only to Huawei

cabinets.

– Static rail kit: applies to cabinets with a distance

of 543.5 mm to 848.5 mm (21.40 in. to 33.41 in.)

between the front and rear mounting bars.

– Ball bearing rail kit: applies to cabinets with a

distance of 610 mm to 914 mm (24.02 in. to

35.98 in.) between the front and rear mounting

bars.

Weight in full

configuration

● Maximum net weight:

– Server with 8 x 2.5" drives: 25.1 kg (55.35 lb)

Full configuration: 8 x 2.5" front 4 x 2.5"

rear drives (I/O module 3)

– Server with 12 x 3.5" drives: 34.1 kg (75.19 lb)

Full configuration: 12 x 3.5" front 2 x

3.5" rear drives (I/O module 1) + 2 x 3.5" rear

drives (I/O module 2) + 4 x 2.5" rear drives (I/O

module 3)

– Server with 24 x 2.5" drives: 29.4 kg (64.83 lb)

Full configuration: 24 x 2.5" front 4 x

2.5" rear drives (I/O module 3)

– Server with 25 x 2.5" drives: 30.5 kg (67.25 lb)

Full configuration: 25 x 2.5" front 2 x

2.5" rear drives (I/O module 1) + 4 x 2.5" rear

drives (I/O module 3)

● Packaging materials: 5 kg (11.03 lb)

Power consumption

The power consumption parameters vary with

hardware configurations (including the configurations

complying with EU ErP). Use the 

Intelligent

Computing Product Power Calculator

 to obtain

specific information.

Huawei FusionServer Pro 2288X V5 Server

Technical White Paper

6 Product Specifications

Issue 03 (2020-04-20)

Copyright © Huawei Technologies Co., Ltd.

66

Содержание FusionServer Pro 2288X V5

Страница 1: ...Huawei FusionServer Pro 2288X V5 Server V100R005 Technical White Paper Issue 03 Date 2020 04 20 HUAWEI TECHNOLOGIES CO LTD ...

Страница 2: ...cribed in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the prep...

Страница 3: ...k which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance dete...

Страница 4: ...ronment deterioration Change History Issue Date Description 03 2020 04 20 This issue is the third official release 02 2020 03 05 The issue is the second official release 01 2019 12 31 This issue is the first official release Huawei FusionServer Pro 2288X V5 Server Technical White Paper About This Document Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd iii ...

Страница 5: ...ifier 22 5 4 2 Memory Subsystem Architecture 23 5 4 3 Memory Compatibility 24 5 4 4 Memory Installation Guidelines 27 5 4 5 Memory Installation Positions 27 5 4 6 Memory Protection Technologies 29 5 5 Storage 29 5 5 1 Drive Configurations 30 5 5 2 Drive Numbering 33 5 5 3 Drive Indicators 35 5 5 4 RAID Controller Card 37 5 6 Network 37 5 6 1 LOMs 37 5 6 2 OCP 2 0 Mezzanine Cards 40 5 7 I O Expansi...

Страница 6: ...8 Safety Instructions 68 8 1 Safety Instructions 68 8 2 Maintenance and Warranty 71 9 System Management 72 10 Certifications 74 A Appendix 75 A 1 Product SN 75 A 2 Operating Temperature Limitations 77 A 3 RAS Features 79 A 4 Sensor List 81 B Glossary 88 B 1 A E 88 B 2 F J 89 B 3 K O 89 B 4 P T 89 B 5 U Z 90 C Acronyms and Abbreviations 91 C 1 A E 91 C 2 F J 92 C 3 K O 93 C 4 P T 94 C 5 U Z 96 Huaw...

Страница 7: ...e services cloud computing high performance computing distributed storage big data processing enterprise or telecom applications and other complex workloads The reliable 2288X V5 features low power consumption high scalability easy deployment and simplified management Figure 1 1 Physical structure of a 2288X V5 with 12 x 3 5 drives example Huawei FusionServer Pro 2288X V5 Server Technical White Pa...

Страница 8: ...OS vendors to better use hardware to address virtualization workloads Intel Advanced Vector Extensions 512 Intel AVX 512 significantly accelerates floating point performance for computing intensive applications The Cascade Lake processors support Intel Deep Learning Boost vector neural network instructions VNNI to improve the performance of deep learning applications The server supports double dat...

Страница 9: ... parts replacement and onsite repair for the servers used in China Huawei provides a 10 hour a day 7 day a week support program Service requests will be handled the next business day Optional service upgrades are available Huawei provides a three year warranty for parts replacement and repair for the servers used outside China Huawei provides a 9 hour a day 5 day a week support program Service req...

Страница 10: ... of multiple power ratings provide 94 power efficiency at 50 load The server supports active standby power supplies and high voltage DC HVDC for improved power supply efficiency Efficient voltage regulator down VRD power supplies for boards minimize the energy loss from DC DC power conversion Area based Proportional Integral Derivative PID intelligent fan speed adjustment and intelligent CPU frequ...

Страница 11: ... O module 2 3 PSUs 4 Chassis 5 I O module 3 6 Supercapacitor holders 7 Air duct 8 Front drive backplane 9 Fan module brackets 10 Fan modules 11 Front drives 12 Heat sinks Huawei FusionServer Pro 2288X V5 Server Technical White Paper 3 Physical Structure Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 5 ...

Страница 12: ...le organizers 16 TPM TCM 17 Mainboard 18 Screw in RAID controller card 19 OCP 2 0 mezzanine cards Huawei FusionServer Pro 2288X V5 Server Technical White Paper 3 Physical Structure Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 6 ...

Страница 13: ...rocessors through PCIe buses to provide ease of expandability and connection CPUs 1 and 2 each support one OCP 2 0 mezzanine card The RAID controller card on the mainboard connects to CPU 1 through PCIe buses and connects to the drive backplane through SAS signal cables A variety of drive backplanes are provided to support different local storage configurations Huawei FusionServer Pro 2288X V5 Ser...

Страница 14: ...s The server uses Hi1710 management chip and supports a video graphic array VGA port a management network port and a debug serial port Huawei FusionServer Pro 2288X V5 Server Technical White Paper 4 Logical Structure Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 8 ...

Страница 15: ...ge 5 6 Network 5 7 I O Expansion 5 8 PSUs 5 9 Fans 5 10 Boards 5 1 Front Panel 5 1 1 Appearance 8 x 2 5 drive configuration Figure 5 1 Front view Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 9 ...

Страница 16: ...s 2 Slide out label plate with an SN label 24 x 2 5 drive configuration Figure 5 3 Front view 1 Drives 2 Slide out label plate with an SN label 25 x 2 5 drive configuration Figure 5 4 Front view Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 10 ...

Страница 17: ...s indicator NOTE The indicator is reserved 4 Non Maskable Interrupt NMI button 5 Fault diagnosis LED 6 Health status indicator 7 UID button indicator 8 Power button indicator 12 x 3 5 drive configuration Figure 5 6 Indicators and buttons on the front panel 1 10GE LOM port 1 connection status indicator 2 10GE LOM port 2 connection status indicator Huawei FusionServer Pro 2288X V5 Server Technical W...

Страница 18: ...tion status indicator 3 GE LOM port connection status indicator NOTE The indicator is reserved 4 Fault diagnosis LED 5 Health status indicator 6 UID button indicator 7 Power button indicator 8 NMI button 25 x 2 5 drive configuration Figure 5 8 Indicators and buttons on the front panel 1 10GE LOM port 1 connection status indicator 2 10GE LOM port 2 connection status indicator Huawei FusionServer Pr...

Страница 19: ...indicator Power indicator Off The device is not powered on Steady green The device is powered on Blinking yellow The power button is locked The power button is locked when the iBMC is starting Steady yellow The device is ready to power on Power button When the device is powered on you can press this button to gracefully shut down the OS When the device is powered on holding down this button for 6 ...

Страница 20: ...linking red at 1 Hz A major alarm has been generated on the system Blinking red at 5 Hz A critical alarm has been generated on the system Steady green The device is operating properly NMI button A non maskable interrupt NMI is generally triggered to stop the OS for debugging To trigger an NMI press this button or click the button on the iBMC WebUI NOTICE Press the NMI button only when the OS is ab...

Страница 21: ...pply and will not be powered off even if the service system is powered off As long as the LOM ports are properly connected to other working network devices the network ports will remain connected and the indicators are on 5 1 3 Ports Port Positions 8 x 2 5 drive configuration Figure 5 9 Ports on the front panel 1 USB 2 0 ports 2 USB 3 0 port 3 VGA port 12 x 3 5 drive configuration Figure 5 10 Port...

Страница 22: ...nt panel 1 USB 2 0 ports Port Description Table 5 2 Ports on the front panel Port Type QuantityNote Description VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM USB port USB 2 0 2 Used to connect to a USB device Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 16 ...

Страница 23: ...ure 5 13 Rear view 1 I O module 1 2 I O module 2 3 I O module 3 4 PSU 2 5 PSU 1 6 Optional OCP 2 0 mezzanine card 2 7 Optional OCP 2 0 mezzanine card 1 8 LOM I O module 1 can be configured with a PCIe riser module or a module with drives and PCIe card I O modules 2 and 3 can be configured with drive modules or PCIe riser modules For details about the LOM and OCP 2 0 mezzanine card see 5 6 Network ...

Страница 24: ...n the rear panel Indicator Description LOM indicators For details see 5 6 1 LOMs OCP 2 0 mezzanine card indicators For details see 5 6 2 OCP 2 0 Mezzanine Cards Data transmission status indicator of the management network port Off No data is being transmitted Blinking yellow Data is being transmitted Connection status indicator for the management network port Off The network port is not connected ...

Страница 25: ... is standby The input is overvoltage or undervoltage The PSU is in deep hibernation mode Blinking green at 4 Hz The firmware is being upgraded online Steady green The power input and output are normal Steady orange The input is normal but no power output is supplied NOTE The possible causes of no power output are as follows Power supply overtemperature protection Power output overcurrent or short ...

Страница 26: ...VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM USB port USB 3 0 2 Used to connect to a USB device NOTICE Before connecting an external USB device check that the USB device functions properly The server may operate abnormally if an abnormal USB device is connected Management network port 1000BASE T 1 Used for server management NOTE The management network port is a GE po...

Страница 27: ...he quantity of PSUs ensure that the rated power of the PSUs is greater than that of the server If only one PSU is used Predicted PSU Status cannot be set to Active Standby on the iBMC WebUI 5 3 Processor The server supports one or two processors If only one processor is required install it in socket CPU1 The same model of processors must be used in a server Contact your local Huawei sales represen...

Страница 28: ...ou can determine the memory module properties based on the label attached to the memory module Figure 5 17 Memory identifier Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 22 ...

Страница 29: ...5 T 17 7 DIMM type R RDIMM L LRDIMM 5 4 2 Memory Subsystem Architecture The 2288X V5 provides 24 memory slots Each processor integrates six memory channels Install memory modules in primary memory channels first If the primary memory channel is not populated the memory modules in secondary memory channels cannot be used Table 5 5 Memory channels CPU Memory Channel Memory Slot CPU 1 A primary DIMM0...

Страница 30: ...M101 G B primary DIMM110 B B DIMM111 H C primary DIMM120 C C DIMM121 I D primary DIMM130 D D DIMM131 J E primary DIMM140 E E DIMM141 K F primary DIMM150 F F DIMM151 L 5 4 3 Memory Compatibility Observe the following rules when configuring DDR4 memory modules Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd...

Страница 31: ...processors 2 TB socket Other processors 1 TB socket The total memory capacity is the sum of the capacity of all DDR4 memory modules NOTICE The total memory capacity cannot exceed the maximum memory capacity supported by the CPUs Use the Intelligent Computing Compatibility Checker to determine the capacity type of a single memory module The maximum number of memory modules supported by a server var...

Страница 32: ...3d 2933d 2DPC 2666 2666 2666 2666 2666 2666 a The maximum number of DDR4 memory modules is based on dual processor configuration The value is halved for a server with only one processor b The maximum DDR4 memory capacity varies depending on the processor type The value listed in this table is based on the assumption that memory modules are fully configured c DPC DIMM per channel indicates the numb...

Страница 33: ...ation guidelines Each processor supports two integrated memory controllers IMCs At least two channels of each IMC are used for installing memory modules channels 1 and 2 or channels 1 2 and 3 The memory modules installed must be identical in size and organization For a multi processor configuration each processor must have a valid memory mirroring configuration Memory scrubbing mode Comply with th...

Страница 34: ...mory slots Figure 5 19 DDR4 memory installation guidelines 1 processor Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 28 ...

Страница 35: ...C Full Mirror Address Range Mirror Rank Sparing Mode Lockstep Failed DIMM Isolation Memory Thermal Throttling Memory Address Parity Protection ADDDC Memory Demand Patrol Scrubbing Data Scrambling ADDDC 1 5 5 Storage Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 29 ...

Страница 36: ... to 47 support only NVMe drives 1 x screw in RAID controller card 8 x 2 5 drive pass through configuration 3 8 x 2 5 Slots 0 to 7 support only SAS SATA drives I O module 3 4 x 2 5 Slots 44 to 47 support only NVMe drives 1 x PCIe RAID controller card 12 x 3 5 drive pass through configuration 1 12 x 3 5 Slots 0 to 11 support only SATA drives I O module 1 2 x 3 5 Slots 40 and 41 support only SATA dri...

Страница 37: ... 44 to 47 support only NVMe drives 1 x screw in RAID controller card 12 x 3 5 drive pass through configuration 3 12 x 3 5 Slots 0 to 11 support only SAS SATA drives I O module 1 2 x 2 5 Slots 40 and 41 support only SAS SATA drives I O module 2 2 x 3 5 Slots 42 and 43 support only SAS SATA drives I O module 3 4 x 2 5 Slots 44 to 47 support only NVMe drives 1 x PCIe RAID controller card Huawei Fusio...

Страница 38: ... 4 x 2 5 Slots 44 to 47 support only NVMe drives 1 x screw in RAID controller card 2 x PCIe RAID controller cardsa 24 x 2 5 drive pass through configuration 2 24 x 2 5 Slots 0 to 23 support only SAS SATA drives I O module 3 4 x 2 5 Slots 44 to 47 support only NVMe drives 3 x PCIe RAID controller cardsa 25 x 2 5 drive EXP configuration 25 x 2 5 Slots 0 to 24 support only SAS SATA drives I O module ...

Страница 39: ... use the Intelligent Computing Compatibility Checker to determine the components to be used 5 5 2 Drive Numbering 8 x 2 5 drive pass through configuration Figure 5 21 Drive numbering 12 x 3 5 drive pass through configuration 1 Figure 5 22 Drive numbering 12 x 3 5 drive pass through configuration 2 Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04...

Страница 40: ...igure 5 24 Drive numbering 12 x 3 5 drive EXP configuration Figure 5 25 Drive numbering 24 x 2 5 drive pass through configuration Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 34 ...

Страница 41: ...ors Figure 5 28 SAS SATA drive indicators Table 5 8 Description of SAS SATA drive indicators Activity Indicator Green Fault Indicator Yellow Description Steady on Off The drive is in position Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 35 ...

Страница 42: ...ed and the latest VMD driver is installed the NVMe drives support surprise hot swap Table 5 9 Description of NVMe drive indicators VMD enabled Activity Indicator Green Fault Indicator Yellow Description Off Off The NVMe drive cannot be detected Steady on Off The NVMe drive is working properly Blinking at 2 Hz Off Data is being read from or written to the NVMe SSD Off Blinking at 2 Hz The NVMe driv...

Страница 43: ...ntroller Card The RAID controller card supports RAID configuration RAID level migration and drive roaming PCIe plug in RAID controller cards and screw in RAID controller cards are supported Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used For details about the RAID controller card see Huawei V5 Server RAID ...

Страница 44: ... duplex Supported rate 10000 Mbit s Rates not supported 10 100 1000 Mbit s The LOM ports do not support forced rates Forcibly powering off a server will cause intermittent NC SI disconnection and disable the Wake on LAN WOL function of the LOM ports To restore the NC SI connection refresh the iBMC WebUI Figure 5 30 LOM ports 1 10GE LOM port 1 2 10GE LOM port 2 Huawei FusionServer Pro 2288X V5 Serv...

Страница 45: ...ndicator for a 10GE optical port Off The network port is not connected Blinking green Data is being transmitted Steady green The network port is properly connected Data transmission rate indicator for a 10GE optical port Off The network port is not connected Steady green The data transmission rate is 10 Gbit s Steady yellow The data transmission rate is lower than 10 Gbit s Huawei FusionServer Pro...

Страница 46: ...er of Ports NC SI WOL PXE OCP 2 0 mezzanin e card 1 CX5 25GE optical port 2 OCP 2 0 mezzanin e card 2 CX5 25GE optical port 2 Indicator Positions OCP 2 0 mezzanine card indicators 2 x 25GE optical ports Figure 5 32 OCP 2 0 mezzanine card indicators 2 x 25GE optical ports 1 Connection status indicator Data transmission status indicator for a 25GE optical port 2 Data transmission rate indicator for ...

Страница 47: ... and connection Eight slots for standard PCIe cards are supported Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used 5 7 2 PCIe Slots PCIe Slots Figure 5 33 PCIe slots I O module 1 provides slots 1 to 3 If a dual slot PCIe riser module is used slot 2 is unavailable If a module with 2 x 2 5 drives and one PCIe...

Страница 48: ... only one HHHL single slot x16 GPU card A two slot PCIe riser module in I O module 3 does not support dual slot GPU cards All GPU cards except HHHL GPU cards must be installed in dedicated PCIe riser modules PCIe Riser Modules PCIe riser module 1 universal Provides PCIe slots 1 and 3 when installed in I O module 1 Provides PCIe slots 4 and 6 when installed in I O module 2 Figure 5 34 PCIe riser mo...

Страница 49: ...e riser module 3 for GPU cards only Provides PCIe slots 1 and 3 when installed in I O module 1 Provides PCIe slots 4 and 6 when installed in I O module 2 Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 43 ...

Страница 50: ... when installed in I O module 3 Figure 5 37 PCIe riser module 4 PCIe riser module 5 Provides PCIe slot 7 when installed in I O module 3 Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 44 ...

Страница 51: ...ser module 6 Provides PCIe slot 3 when installed in I O module 1 Figure 5 39 PCIe riser module 6 Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 45 ...

Страница 52: ... D F Slot Size RAID contro ller card CPU 1 PCIe 3 0 x8 x8 Port3A 5D 00 0 5E 00 0 LOM CPU 1 PCIe 3 0 x8 x8 Port1A 17 00 0 1A 00 0 OCP 2 0 mezza nine card 1 CPU 1 PCIe 3 0 x8 x8 Port1C 17 02 0 1C 00 0 OCP 2 0 mezza nine card 2 CPU 2 PCIe 3 0 x8 x8 Port2A AE 00 0 AF 00 0 Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technolog...

Страница 53: ...Slot 1 CPU 1 PCIe 3 0 x16 2 slot PCI e rise r mo dul e PR M x16 3 slot PR M x8 Mo dul e wit h 2 x 2 5 driv es and one PCI e car d N A Port2A 3A 00 0 3B 00 0 FHFL Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 47 ...

Страница 54: ...dul e wit h 2 x 2 5 driv es and one PCI e car d N A Port2C 3A 02 0 3E 00 0 FHFL Slot 3 CPU 1 PCIe 3 0 x16 x8 Port3C 5D 02 0 5E 00 0 FHHL Slot 4 CPU 2 PCIe 3 0 x16 2 slot PR M x16 3 slot PR M x8 Port1A 85 00 0 86 00 0 FHFL Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 48 ...

Страница 55: ...00 0 FHFL Slot 6 CPU 2 PCIe 3 0 x16 x8 Port2C AE 02 0 B0 00 0 FHHL Slot 7 CPU 2 PCIe 3 0 x16 1 slot PR M x16 2 slot PR M x8 Port3A D7 00 0 D8 00 0 HHHL Slot 8 CPU 2 PCIe 3 0 x8 1 slot PR M N A 2 slot PR M x8 Port3C D7 02 0 DB 00 0 HHHL Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 49 ...

Страница 56: ...t half length FHHL PCIe slots are backward compatible with half height half length HHHL PCIe cards All slots support PCIe cards of up to 75 W The power of a PCIe card varies depending on its model The SP520 SP521 and SP522 do not support driveless server configuration PXE boot is recommended for driveless servers 5 8 PSUs The server supports one or two PSUs The server supports AC or DC PSUs The PS...

Страница 57: ...s failure of a single fan The fan speed can be adjusted The same model of fan modules must be used in a server Figure 5 41 Fan module positions 5 10 Boards Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 51 ...

Страница 58: ...etwork port BMC GE J180 5 2 x USB 3 0 ports USB3 0 CONN J169 6 VGA connector VGA J112 7 USB 3 0 port INNER USB3 0 J181 8 OCP 2 0 mezzanine card 1 slot OCP1 J178 9 2 x 10GE optical ports 10GE PORT J88 J89 10 VROC key port VROC KEY J130 a Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 52 ...

Страница 59: ...45 27 Intrusion sensor connector INTRUDER S1 a 28 Fan 2 connector 2U FAN2 J146 29 Fan 1 connector 1U 2U FAN1 J105 30 Drive backplane connector HDD BP CONN J162 31 Built in drive power connector INNER HDD PWR J171 a 32 Drive backplane power connector 1 HDD BP PWR1 J128 33 Drive backplane power connector 2 HDD BP PWR2 J166 34 Rear drive backplane power connector 3 REAR BP PWR3 J182 35 Rear 4 x 2 5 i...

Страница 60: ...ass through backplane Figure 5 43 8 x 2 5 drive pass through backplane BOM 03026VRB 1 Indicator signal cable connector REAR BP1 J3 NOTE The connector is reserved 2 DVD drive power connector DVD J11 3 Backplane signal cable connector HDD BP J1 4 Power connector POWER J2 5 mini SAS HD connector PORT A J28 6 mini SAS HD connector PORT B J29 12 x 3 5 drive pass through backplane Huawei FusionServer Pr...

Страница 61: ...ctor POWER J1 12 x 3 5 drive EXP backplane Figure 5 45 12 x 3 5 drive EXP backplane BOM 03027FAT 1 Indicator signal cable connector REAR BP0 J31 2 mini SAS HD connector PORT A J28 3 mini SAS HD connector PORT B J29 4 mini SAS HD connector REAR PORT J34 5 Backplane signal cable connector HDD BP J35 6 Power connector POWER J24 7 Indicator signal cable connector REAR BP1 J32 Huawei FusionServer Pro 2...

Страница 62: ...er connector POWER J24 8 Backplane signal cable connector HDD_BP J1 25 x 2 5 drive EXP backplane Figure 5 47 25 x 2 5 drive EXP backplane BOM 03027QFN 1 Indicator signal cable connector REAR BP0 J32 2 mini SAS HD connector PORT A J28 3 mini SAS HD connector PORT B J29 4 mini SAS HD connector REAR PORT J31 5 Backplane signal cable connector HDD_BP J1 6 Power connector POWER J24 Huawei FusionServer ...

Страница 63: ... 5 drive backplane BOM 03026XYQ 1 Power connector BP PWR J1 2 Indicator signal cable connector REAR BP J5 3 mini SAS HD connector REAR PORT J2 2 x 3 5 drive backplane Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 57 ...

Страница 64: ...PORT J2 3 Power connector BP PWR J1 4 x 2 5 drive backplane Figure 5 50 4 x 2 5 drive backplane BOM 03026XBS 1 Power connector REAR BP PWR3 J24 2 Slimline A connector SLIMLINE A J8 Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 58 ...

Страница 65: ...E B J9 4 mini SAS HD connector PORT A J2 5 Backplane signal cable connector HDD BP J23 Huawei FusionServer Pro 2288X V5 Server Technical White Paper 5 Hardware Description Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 59 ...

Страница 66: ...controller and six memory channels Built in PCIe controller supporting PCIe 3 0 and 48 lanes per processor Two UPI buses between processors providing up to 10 4GT s transmission per channel Up to 28 cores 2 7 GHz Max 3 8 GHz four cores Min 1 375 MB L3 cache per core Max 205 W TDP NOTE The preceding information is for reference only Use the Intelligent Computing Compatibility Checker to obtain spec...

Страница 67: ... latest Intel VMD driver is installed Orderly hot swap if the VMD function is disabled Supports a variety of RAID controller cards Use the Intelligent Computing Compatibility Checker to obtain information about the specific RAID controller cards supported The RAID controller card supports RAID configuration RAID level migration and drive roaming The RAID controller card does not occupy a standard ...

Страница 68: ...sion 11 PCIe 3 0 slots One slot dedicated for a RAID controller card two dedicated for OCP 2 0 mezzanine cards and eight for standard PCIe cards For details see 5 7 2 PCIe Slots and 5 7 3 PCIe Slot Description Support Huawei proprietary PCIe SSD cards to bolster I O performance for applications such as searching caching and download services Supports GPU cards NOTE The preceding information is for...

Страница 69: ...0 video chip with 32 MB display memory is integrated on the mainboard The maximum display resolution is 1920 x 1200 at 60 Hz with 16 M colors NOTE The integrated video card can provide the maximum display resolution 1920 x 1200 only after the video card driver matching the operating system version is installed Otherwise only the default resolution supported by the operating system is provided If b...

Страница 70: ...ing with ASHRAE Class A2 is used in a place above 900 m 2952 76 ft the highest operating temperature decreases by 1 C 1 8 F for every increase of 300 m 984 25 ft If the server complying with ASHRAE Class A3 is used in a place above 900 m 2952 76 ft the highest operating temperature decreases by 1 C 1 8 F for every increase of 175 m 574 15 ft If the server complying with ASHRAE Class A4 is used in ...

Страница 71: ...73 4 F in accordance with ISO 7779 ECMA 74 and declared in accordance with ISO 9296 ECMA 109 Idle LWAd 5 64 Bels LpAm 42 2 dBA Operating LWAd 6 08 Bels LpAm 46 8 dBA NOTE Actual sound levels generated during operation vary depending on server configuration load and ambient temperature 6 3 Physical Specifications Table 6 3 Physical specifications Category Description Dimensions H x W x D Chassis wi...

Страница 72: ... 2 5 front drives 4 x 2 5 rear drives I O module 3 Server with 12 x 3 5 drives 34 1 kg 75 19 lb Full configuration 12 x 3 5 front drives 2 x 3 5 rear drives I O module 1 2 x 3 5 rear drives I O module 2 4 x 2 5 rear drives I O module 3 Server with 24 x 2 5 drives 29 4 kg 64 83 lb Full configuration 24 x 2 5 front drives 4 x 2 5 rear drives I O module 3 Server with 25 x 2 5 drives 30 5 kg 67 25 lb ...

Страница 73: ...re supported NOTICE Do not use incompatible components Otherwise the server may fail to work properly The technical support and warranty do not cover faults caused by incompatible components Huawei FusionServer Pro 2288X V5 Server Technical White Paper 7 Software and Hardware Compatibility Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 67 ...

Страница 74: ... a forklift Take protective measures if a Class A product is used in residential areas as it is likely to cause radio interference Personal Safety Only personnel certified or authorized by Huawei are allowed to install the hardware Stop any operation that may cause personal injury or equipment damage report the problem to a project supervisor immediately and take protective measures Do not operate...

Страница 75: ...ure 8 2 Conductive objects to be removed Figure 8 3 shows how to wear an ESD wrist strap a Secure the ESD wrist strap around your wrist b Fasten the strap buckle and ensure that the ESD wrist strap is in contact with your skin c Insert the ground terminal attached to the ESD wrist strap into the jack on the grounded rack or chassis Huawei FusionServer Pro 2288X V5 Server Technical White Paper 8 Sa...

Страница 76: ... of the device Do not hold the handles of the installed modules such as the PSUs fan modules drives and the mainboard Handle the equipment with care Exercise caution when using tools that could cause personal injury Connect the primary and secondary power cables to different power distribution units PDUs to ensure reliable system operation Properly ground a device before powering it on Transportat...

Страница 77: ... a number of organizations Table 8 1 Maximum weight one person is permitted to carry Organization Weight kg lb European Committee for Standardization CEN 25 55 13 International Organization for Standardization ISO 25 55 13 National Institute for Occupational Safety and Health NIOSH 23 50 72 Health and Safety Executive HSE 25 55 13 General Administration of Quality Supervision Inspection and Quaran...

Страница 78: ...nd text console redirection Remote virtual media IPMI SNMP Common information model CIM Redfish Browser based login Specifications Table 9 1 iBMC specifications Feature Description Management interface Integrates with any standard management system through the following interfaces or protocols IPMI CLI HTTPS SNMP Redfish Fault detection Detects and accurately locates faults in hardware for example...

Страница 79: ...erations Fault reproduction Reproduces faults to help diagnose them quickly Screen snapshots and screen videos Allows users to view screenshots and videos without login facilitating routine preventive maintenance inspection PMI Black Box Allows users to enable or disable the black box function and download black box data DNS LDAP Supports domain management and directory services significantly simp...

Страница 80: ...egion Certification Standards China CCC GB4943 1 2011 GB9254 2008 Class A GB17625 1 2012 Huawei FusionServer Pro 2288X V5 Server Technical White Paper 10 Certifications Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 74 ...

Страница 81: ...le Table A 1 SN description Callout No Description 1 SN ID two characters which is 21 2 Material identification code 8 characters that is the processing code 3 Vendor code two characters 10 indicates Huawei and other values indicate outsourcing vendors Huawei FusionServer Pro 2288X V5 Server Technical White Paper A Appendix Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 75 ...

Страница 82: ... 2010 are represented by uppercase letters excluding I O and Z because the three letters are similar to digits 1 0 and 2 The second character indicates the month Digits 1 to 9 indicate January to September respectively Letters A to C indicate October to December respectively 5 Sequence number six characters 6 RoHS compliance one character Y indicates RoHS compliant 7 Internal model that is product...

Страница 83: ...m 8153 Gold 6152 6140 6126 5118 5215 Silver 4216 4215 4214 and other processors lower than 105 W Options not supported PCIe SSD cards Passive GPU cards Rear drives IB and OPA cards OCP 2 0 mezzanine cards 12 x 3 5 drive pass through configuration V100 GPU cards not supported Options not supported V100 GPU cards T4 GPU cards Options not supported PCIe SSD cards Passive GPU cards Rear drives OCP 2 0...

Страница 84: ...ration V100 GPU cards not supported Options not supported V100 GPU cards T4 GPU cards Options not supported PCIe SSD cards Passive GPU cards Rear drives OCP 2 0 mezzanine cards 25 x 2 5 drive EXP configuration V100 GPU cards not supported Options not supported V100 GPU cards T4 GPU cards Options not supported PCIe SSD cards Passive GPU cards Rear drives OCP 2 0 mezzanine cards Huawei FusionServer ...

Страница 85: ...re configured The maximum operating temperature is 40 C 104 F in the 8 x 2 5 drive pass through configuration The maximum operating temperature is 35 C 95 F in the 12 x 3 5 and 24 x 2 5 drive pass through configurations The maximum operating temperature is 35 C 95 F in the 12 x 3 5 and 25 x 2 5 drive EXP configurations A 3 RAS Features The server supports a variety of Reliability Availability and ...

Страница 86: ...a streams in the memory and the capability to detect address errors PCIe PCIe Advanced Error Reporting Improves server serviceability UPI Intel UPI Link Level Retry Provides a retry mechanism upon errors to improve UPI reliability Intel UPI Protocol Protection via CRC Provides cyclic redundancy check CRC protection for UPI packets to improve system reliability System Core Disable for Fault Resilie...

Страница 87: ...orm Environment Control Interface PECI If a fatal error occurs in the system the out of band system collects onsite data to facilitate fault analysis and locating and improve system serviceability BIOS Abstraction Layer for Error Handling The BIOS processes errors and reports the error information to the OS and the server in compliance with specifications to improve system serviceability BIOS base...

Страница 88: ...rature DIMMs of CPUN N indicates the CPU number The value is 1 or 2 OCPN Temp OCP 2 0 mezzanine card chip temperature Chip of OCPN N indicates the slot number of the OCP 2 0 mezzanine card The value is 1 or 2 OCPN OP Temp OCP 2 0 mezzanine card optical module temperature Optical module of OCPN N indicates the slot number of the OCP 2 0 mezzanine card The value is 1 or 2 SYS 3 3V Mainboard 3 3 V vo...

Страница 89: ...ard N indicates the CPU number The value is 1 or 2 CPUN VMCP CPU VMCP voltage Mainboard N indicates the CPU number The value is 1 or 2 FANN Speed Fan speed Fan moduleN N indicates the fan module number The value ranges from 1 to 4 Power Server input power PSU PSN VIN Input voltage of PSUN PSUN N indicates the PSU number The value is 1 or 2 Disks Temp Maximum temperature of SAS SATA drives SAS SATA...

Страница 90: ...moduleN N indicates the fan module number The value ranges from 1 to 4 DIMMN DIMM status DIMMN N indicates the DIMM slot number RTC Battery RTC battery status An alarm is generated when the voltage is lower than 1 V RTC battery PCIE Status PCIe status PCIe cards Power Button Power button pressed state Mainboard and power button Watchdog2 Watchdog Mainboard Mngmnt Health Management subsystem health...

Страница 91: ...controller card presence RAID controller card LCD Status LCD health status LCD LCD Presence LCD presence LCD PS Redundancy Redundancy failure due to PSU removal PSU PSN Status PSU status PSUN N indicates the PSU number The value is 1 or 2 PSN Fan Status PSU fan status PSUN N indicates the PSU number The value is 1 or 2 PSN Temp Status PSU presence PSUN N indicates the PSU number The value is 1 or ...

Страница 92: ...d chip temperature PCIe cards PCIe FC Temp PCIe card chip temperature PCIe cards RAID Card BBU RAID controller card BBU BBU supercapacitor of RAID controller card SM380 Temp 25GE NIC chip temperature PCIe cards PCIe NIC Temp PCIe card chip temperature PCIe cards PS Inlet Temp PSU air inlet temperature PSU CPUN AEP Temp CPU DCPMM temperature DCPMMs of CPUN N indicates the CPU number The value is 1 ...

Страница 93: ...cription Component FPGA OP Temp FPGA card optical module temperature PCIe cards Huawei FusionServer Pro 2288X V5 Server Technical White Paper A Appendix Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 87 ...

Страница 94: ...e the objects E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox Corporation by partnering with Intel and DEC Ethernet uses the Carrier Sense Multiple Access Collision Detection CSMA CD access method and allows data transfer over various cables at 10 Mbit s The Ethernet ...

Страница 95: ...rver It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility EMC Peripheral Component Interconnect Express PCIe A computer bus PCI which uses the existing PCI programming concepts and communication standards but builds a faster serial communication system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI syste...

Страница 96: ...ecial computer that provides services for clients over a network system event log SEL A non volatile area and interfaces used to store system events for later fault diagnosis and system recovery B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet or chassis 1 U 44 45 mm UltraPath Interconnect UPI A point to point processor intercon...

Страница 97: ...Vector Extensions B BBU backup battery unit BIOS Basic Input Output System BMC baseboard management controller C CD calendar day CE Conformite Europeenne CIM Common Information Model CLI command line interface Huawei FusionServer Pro 2288X V5 Server Technical White Paper C Acronyms and Abbreviations Issue 03 2020 04 20 Copyright Huawei Technologies Co Ltd 91 ...

Страница 98: ...an Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber Channel FCC Federal Communications Commission FCoE Fibre Channel over Ethernet FTP File Transfer Protocol G GE Gigabit Ethernet Huawei FusionServer Pro 2288X V5 Server Technical White Paper C Acr...

Страница 99: ...ternet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations per second IP Internet Protocol IPC intelligent power capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface C 3 K O K KVM keyboard video and mouse Huawei FusionServer Pr...

Страница 100: ... Controller Sideband Interface C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK power OK PWM pulse width modulation PXE Preboot Execution Environment Q QPI Quick Path Interconnect Huawei FusionServer Pro 2288X V5 Server Technical White Paper C Acronyms and Abbreviations Issue 03 2020 04 20 Copyright Huawei Techno...

Страница 101: ... single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SOL serial over LAN SONCAP Standards Organization of Nigeria Conformity Assessment Program SSD solid state drive SSE Streaming SIMD Extensions T TACH tachometer signal TBT Turbo Boos...

Страница 102: ... Interface UID unit identification light UL Underwriter Laboratories Inc USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by Information Technology Equipment VGA Video Graphics Array VLAN virtual local area network VRD voltage regulator down W WEEE waste electrical and electronic equipment WSMAN Web Service Management Huawei FusionServer Pro 2288X V5 Server Technical Whit...

Отзывы: