Category
Specifications
Particle contaminant
● The equipment room environment meets the
requirements of ISO 14664-1 Class 8.
● There is no explosive, conductive, magnetic, or
corrosive dust in the equipment room.
NOTE
It is recommended that the particulate pollutants in the
equipment room be monitored by a professional organization.
Acoustic noise
The declared A-weighted sound power levels (LWAd)
and declared average bystander position A-weighted
sound pressure levels (LpAm) listed are measured at
23°C (73.4°F) in accordance with ISO 7779 (ECMA 74)
and declared in accordance with ISO 9296 (ECMA 109).
● Idle:
– LWAd: 5.64 Bels
– LpAm: 42.2 dBA
● Operating:
– LWAd: 6.08 Bels
– LpAm: 46.8 dBA
NOTE
Actual sound levels generated during operation vary
depending on server configuration, load, and ambient
temperature.
6.3 Physical Specifications
Table 6-3 Physical specifications
Category
Description
Dimensions (H x W x
D)
● Chassis with 3.5" drives: 87.5 mm x 447 mm x 750
mm (3.44 in. x 17.60 in. x 29.53 in.)
● Chassis with 2.5" drives: 86.1 mm x 447 mm x 708
mm (3.39 in. x 17.60 in. x 27.87 in.)
Huawei FusionServer Pro 2288X V5 Server
Technical White Paper
6 Product Specifications
Issue 03 (2020-04-20)
Copyright © Huawei Technologies Co., Ltd.
65