2.1.4 Phones Connected to the IAD Can Ring but Nothing Is
Heard After Pickup
Symptom
When outer-office user A dials IAD user B, user B's phone rings, and user A can hear the RBT.
However, user B cannot hear user A's voice after user B picks up the phone.
Cause
The signaling carries events that the IAD does not support.
Solution
Step 1
Capture packets on the faulty IAD.
Step 2
Analyze the packets captured on the faulty IAD. Check whether the IAD sends a 518 error
code to the softswitch.
The IAD does not support softswitch messages that contain FXR/T38 events. Common M DCX
messages do not contain FXR/T38 events.
If yes, change the T38 mode to transparent transmission mode for the softswitch.
If no, go to
Step 3
Contact Huawei technical support.