Parameter
Description
Value
slot
Slot of the target
firmware.
1 or 2
NOTE
l
If this parameter is not specified, a slot with
firmware not in use will be selected.
l
If firmware in slot 1 is in use, slot 2 will be
selected by default.
l
A SAS SSD has only one slot, namely, slot 1.
activeflag
Firmware activation
mode.
l
0
: Downloaded firmware is activated after
the next reset.
l
1
: Firmware is activated immediately after
being downloaded.
NOTE
If this parameter is not set, the downloaded firmware
is activated after the next reset.
Usage Guidelines
None
Example
# Download the
nvme0
firmware and make it activated after the next reset.
[root@localhost tool]#
hioadm updatefw -d nvme0 -f ES3000_FW_2.08.bin -s 2 -a 0
slot version activation
1 1010 next
2 1011 current
WARNING! You have selected slot <2> to update the firmware image.
WARNING! You have selected the update firmware operation.
Proceed with the update firmware operation? (Y|N):
y
Please do not remove driver or SSD device
Loading... OK
Downloading and replacing the firmware image at slot <2> succeeded.
Activating the firmware image at slot <2> succeeded.
6.2.3 Activating the Firmware of an SSD
Function
This command is used to activate the firmware of an SSD.
If you run the following command with
activeflag
set to
1
(that is, firmware will be activated
immediately), services may be interrupted. Before running this command, ensure that
stopping services has no adverse impact.
ES3000 V5 NVMe PCIe SSD
User Guide
6 Command Description
Issue 07 (2019-03-19)