Horizontal Port, Upward Cable
≥50mm
≤100mm
ǹ
Ķ
Bending Radius Requirements
l
The bending radius of a 7/8'' feeder must be more than 250 mm, and that of a 5/4'' feeder
must be more than 380 mm.
l
The bending radius of a 1/4" jumper, 1/2" super-flexible jumper, and 1/2" common
jumper must be greater than 35 mm, 50 mm, and 127 mm, respectively.
l
The bending radius of a ground cable must be greater than or equal to five times the
cable diameter.
l
The bending radius of a network cable must be greater than or equal to five times the
cable diameter (that is, 50 mm).
6.9 Power Adaptation Solution
Select a suitable power supply mode as required.
DC Power Supply
Table 6-33
Mapping between device models and DC power adapters
Pa
rt
Nu
m
be
r
Name
Vendor
Applicable Device
02
31
0JF
D
S5700
Series,ES0W2PSD0150,150W DC
Power Module
HUAWEI
AC6605
02
22
011
9
Adapter,0degC,40degC,90V,264V,
+48V/2.08A
FSP
AD9430DN-12
AP2050DN,
AP2050DN-E
AP7050DN-E
R250D-E
AP8082DN and AP8182DN
Hardware Installation and Maintenance Guide
6 Appendix
Issue 03 (2019-04-01)