15

connected. 

2.

 

The data  processor at the 

back of the soft LED display 

input or output no signal. 

Check whether the signal wire between 

controller and PCB is well connected 

3.

 

The connector of the signal 

wire  between  Soft  LED 

display and the receiver is 

not connected correctly 

Check the connector, fasten the locknut 

again, make sure the connector touch 

together 

4.

 

Power adapter spoiled 

Replace the Power adapter 

Some pixel is 

not working 

LED damaged 

Replace LED 

Some  row  or 

column  LED 

is not working 

The connect wire between pixel 

is not well connected 

Take off protection clothing at the back of 

the  soft  LED  display,  check  row  wire  

connection, renew the connection wire and 

cover the shell. 

 

1.

 

Maintenance and replacement of the power adapter. 

Caution: cut off all power before replacing and maintaining the power 

adapter. 

Technical parameter of the power adapter 

   Input voltage: AC 90~260V 50~60Hz. 

   Output voltage: DC 5V 5A 

   Size: L14

5×W22×H28mm 

Power Adapter figure 

                                   

 

The power adapter is installed at back of the soft LED display, which is connected in series.

 

Power Adapter connecting figure

 

Содержание FLC-2500

Страница 1: ...e from lacerating the product 8 Prohibit sinking into the pouring water or other liquid 9 Handle with care when install and disassembly the Soft LED display to avoid the damage of the connecting wire...

Страница 2: ...24 Brightness level 16 levels Renovation frequency 180Hz Fresh frequency 60Hz Color 16 7M R 256 G 256 B 256 Installing mode Hang suspending Weather protection IP44 Application environment Indoor and s...

Страница 3: ...Soft LED display is damaged whether all accessories is all all ready The accessiries include supporting steel stick tube hanging belt spare parts 2 Unfold the Soft LED display insert supporting steel...

Страница 4: ...4 How to combine several piece of soft LED display There are bracket around every soft LED display after adjusting the distance between two curtain fasten the bracket by screw...

Страница 5: ...n can be adjusted 2 The connection of power cable and signal cable There are power cable and signal cable at the back of every Soft LED display after fixing well the Soft LED display please connect th...

Страница 6: ...one by one signed with serial number as 1 2 3 4 5 6 7 8 then lock the nut on the plug At the right sides of the soft LED display there is a output power wcable signed DC 5V connect it with receiver 2...

Страница 7: ...urtai should be face to face Caution If there is water or dirt on the Soft LED display Please dry and clean Soft LED display display before packing When folding the Soft LED display the surface of the...

Страница 8: ...software Click the software setup as shown in below figure And then will appear a dialog box as shown in below figure As soon as the above dialogue box appears input linsn then password 168 Computer s...

Страница 9: ...le size signal trend etc then apply the suitable connecting program from the firmware Before doing the intelligent setup user must collect the info of the following picture the info can also get from...

Страница 10: ...10 Save on receiver Click this item can save data in receiving card permanently If not the data lost when power is down Intelligent setups are shown below Click the intelligent setup Next Next...

Страница 11: ...11 Next Next Next...

Страница 12: ...12 Next Next Next...

Страница 13: ...13 Next Chose send to receiver Next...

Страница 14: ...aince Trouble and solution Trouble Problem Solve 1 The LAN cable between PC and receiver is not well connected Check the LAN cable connection or change the LAN cable 2 The sending card or receiver is...

Страница 15: ...damaged Replace LED Some row or column LED is not working The connect wire between pixel is not well connected Take off protection clothing at the back of the soft LED display check row wire connectio...

Страница 16: ...situation if the power adapter is broken or the connector doesn t touch together completely 1 The LED in back area in horizonal dashed area will not work from the broken one 2 All LED in dashed area w...

Страница 17: ...g use multimeter to test whether the AC and DC output voltage is steady if without output voltage or unsteady replace the power adapter Replace the power adapter Plug out the connecter at two end of t...

Страница 18: ...d whether the column wire is broken off if breaking off solder the column wire on the PCB board then fasten the back cover with screw If the color of two column LED 8 pixels is not correct or lack one...

Страница 19: ...19 4 To maintain LED as per the following steps The end...