20
Gamma
and
LookUpTable
are on opposite sides. When Gamma is enabled, LUT is
unavailable. To make it available, set Gamma value to 1.
Frequency Converter
3.13
Currently this function is not available.
You can manage the frequency converter function.
Frequency converter
Figure 3-36
Table 3-7
Frequency converter parameter description
Parameter
Description
FrequencyConverterSelector
Select frequency converter.
InputSource
Select the input signal source for the frequency converter to
process.
Divider
Configure the divider index.
Multiplier
Configure the multiplier index.
Enable the frequency converter. Multiplier first and then divider. For example, the image line
height is 2048, trigger frequency is 2048, and the actual frame rate is (2048/2048 × Multiplier)
/Divider = 1 frame.
If we set the divider value to 2, then the frame rate is 0.5. Set multiplier value to 2 then the
frame rate is 2.
Set frequency converter (1)
Figure 3-37