User's Manual
HT8000-I/HT8000-II/HT8000-VI
2 Hardware Architecture
Version 1.4(Oct.2019)
Beijing Huahuan Electronics Co., Ltd.
61
A1PS-MC-P12 provides an MON port for on-line monitor optical signals.
A1PS-MC-P12 provides the interface between the system and the network
management system, works with the network management system to
manage each card of the device, and realizes the communication between
the devices.
On the front panel of A1PS-MC-P12, 1 MON interface is used to online
monitor optical signals; 1 OUT interface is used to output the amplified
signals; 1 IN interface is used to input signals to be amplified, 1 NM
interface and 1 CONSOLE interface are used as monitoring interfaces, 1
OSC interface is used to supervise channel signal transmission. The front
panel diagram is shown in Figure 2-32, 3 LEDs are described in Table
Figure 2-32
The front panel diagram of A1PS-MC-P12
OUT
IN
A1PS-MC-P12
PA
NC
MON
CONSOLE
NM
RUN
ALM
OSC
Table 2-35
LED functional descriptions of A1PS-MC-P12
LED
Color Descriptions
RUN
Green
System running indication:
Blink: running normally
Off: running abnormally
ALM
Red
Alarm status indication:
On: alarm occurs
Off: no alarm