- 8 - TDMUX-16 User Manual V1.2
Table 2.3.3-1 Dip Switches Definition
2.4.4
E1/T1Port
There are 8~16 E1 ports on the rear panel by configuring 1~2 E1/T1 cards. The
E1 ports impendence are E1-120
Ω
for twisted pair cables or 75
Ω
for coax. The
E1-120
Ω
(
T1-100
Ω
)
RJ45 sockets are default for ports.
8
1
Fig 2.4.3 RJ45 connector pin sequence
Dip
number
Label
State
E1/T1 card indicators definition
Note
1
st
LED_MODE
ON
E1/T1 packet loss alarm indication
On: Ethernet interface can not receive
E1/T1
Blink: Ethernet interface has packet
loss
Off: Ethernet interface has E1/T1
packet loss
Blink: normal
Only when
the 2
nd
dip
switch is set
OFF, this
dip settings
will be
valid.
OFF
E1/T1 signal alarm status indication
On: E1/T1 interface signal loss
Blink: E1/T1 interface AIS alarm
Off: normal
2
nd
ON
Remote equipment link status
indication
On: addressing remote MAC
Off: not addressing remote MAC
OFF
Set accord to the 1
st
dip switch
3
rd
NO_VLAN
ON
Software VLAN set disabled
It could be
used when
VLAN list
is
configured
wronly,
leading to
management
can not
work
OFF
Software VLAN set valid
4
th
TMP_IP
ON
Default IP address 192.192.192.192
OFF
Manually set IP address