Beijing Huahuan Electronics Co., Ltd.
22
H0FL-EthMux.SA1601/SA1602 User’s Manual V1.3
Web Server NM of H0FL-EthMux SA1602 will be introduced in the
following part.
5.1
System Info
After login Web Server, Welcome page will be shown. This page includes
Hardware version number, Software version number, Web manager version
number, IP address, Subnet Mask, Gateway IP address and MAC address. IP
address, Subnet address and Gateway address can be modified by customer,
while others are only for querying, as shown in Figure 5.1-1. The default
setting IP address is 192.168.1.2.
Figure
5.1-1 System Info
5.2
Alarm State
Alarm state includes E1 Channel, Ethernet Port, Power Supply and Alarm
Log test.
5.2.1
E1 Channel State
Click left side of Alarm State–E1 Channel will show E1 channel Service
Name, Loopback state, E1 Port LOS, AIS alarm, Packet loss alarm, Packet loss
count and far-end connection state. E1 loopback is for testing connection,
loopback is defined in 3.1.2. E1 Loopback setting will become effective after