Huaao NBC series Скачать руководство пользователя страница 16

3.Controller 

The controller is installed on the wire feeder. Figure 4 shows the panel. 

 

(1)

 

Current Adjusting Knob 

The knob is used to adjust the welding current. 

(2)

 

Manual Wire Feeding Knob 

The knob is used to feed wire quickly. 

(3)

 

Voltage Adjusting Knob 

At the separate adjustment mode, the knob is used to adjust the welding voltage; 

At the one-knob intelligent adjustment mode, the sign on the knob must be directed at "standard". 

You  can  finely  tune  the  voltage  within  a  range  of  +/-8V  by  turning  the  knob  slightly  to  left  or 

right. 

4.RD-I Digital Controller 

The controller is optional. To use this controller, plug the control plug into the control socket as 

shown in figure (1) 1.4. For details on the usage, see Instructions to RD-I Digital Controller. 

Note: Once RD-I digital controller is installed, the  adjustment  function of the  original controller 

(as  shown  in  figure  4)  and  control  panel  (figure  2)  will  fail.  All  parameters  are  adjusted  by  the 

RD-I digital controller. 

4.Others 

For  details  on  safety  precautions,  maintenance  method,  and  technical  parameters,  see  the  user 

guide and operation manual of gas shielded welder. 

 

 

 

 

 

 

 

 

 

Current adjustment 

Voltage adjustment 

Manual wire feeding 

Standard 

Содержание NBC series

Страница 1: ...chines Save this manual and keep it handy for quick reference Pay particular attention to the safety instructions we have provided for your protection Contact your distributor if you do not fully unde...

Страница 2: ...arts please contact the local dealers maintain stations with the Warranty Retention of users or a copy of invoice as a certificate so as to get specified maintain service If the user can not provide t...

Страница 3: ...will be caused The symbol above is applicable to the general occasion The serious injury mentioned above refers to eyesight damage trauma harm electric shock fracture and poisoning and so on which wil...

Страница 4: ...Work to the following items in case of electric shock Once contact the position with electricity the fatal electric shock or heat injury will be caused 1 Never contact electrified position 2 Invite el...

Страница 5: ...ing area 4 When weld the steel plate with electroplate or coating the harmful dust and gas will produce please use protection appliance for breath Arc light will cause the inflammation of eye or heat...

Страница 6: ...en the gas bottle is unused 8 Never put welding torch on the gas bottle electrode can not contact gas bottle 1 Never use welding machine on the condition of dismounting machine shell 2 Invite the prof...

Страница 7: ...gging work 2 To prevent insulation deterioration caused by powder accumulation please be sure to maintain and examine and repair regularly 3 If splashing iron powder etc go in the power please be sure...

Страница 8: ...contents 1 NBC DIGITAL series welding machine application and feature 2 equipment install and connection 3 operation and manual 4 others 5 Appendix A Feedback Table...

Страница 9: ...h preceding NBC II series welding machine it has the following new functions and features Better appearance of weld lower possibility of deformation Higher success rate of arc starting due to the appl...

Страница 10: ...welding cable from a wire feeder 1 3 indicates a negative terminal which connects the output cable that connects the workpiece 1 4 indicates a control socket connecting the RD 1 digital controller opt...

Страница 11: ...ng 1 two steps working mode Turn on the switch on the welding torch to start welding and turn off it to stop welding This working mode is applicable to short seam welding 2 Four steps working mode Pre...

Страница 12: ...he arc stopping voltage knob and electrical inductance knob and last for one second the diameter specifications of currently used welding wire is invoked which is favorable for sampling and maintenanc...

Страница 13: ...f time regulating for lead gas transmission In this case the digital tube displays 811 and indicator S is on Turn the arc stopping voltage knob to adjust the time of lead gas transmission which ranges...

Страница 14: ...g of preset current and preset wire feed rate 1 When you press simultaneously the arc stopping current button and arc stopping voltage button and hold them for one second the digital tube displays the...

Страница 15: ...NBC 500III NBC 630III Input power 3 Phase AC380V 3 Phase AC380V 3 Phase AC380V Cable Input side 2 5 mm2 6 mm2 10 mm2 Output side 35 mm2 70 mm2 95 mm2 Ground cable 2 5 mm2 6 mm2 10 mm2 4 Ground Bolt T...

Страница 16: ...the knob slightly to left or right 4 RD I Digital Controller The controller is optional To use this controller plug the control plug into the control socket as shown in figure 1 1 4 For details on th...

Страница 17: ...Wiring diagram Main control board Driver board Front panel Wire feeder...

Страница 18: ...Jinan Huaao electric welding machine Co Ltd No 182 41 Gongye North Rd Lieheng Jinan Shandong 250100 China Tel 0531 8863 8666 Fax 0531 8866 5381 E mail yu xia jnhuaao cn http www jnhuaao cn...

Отзывы: