HTW VAX HTW-ATS-O-500VAX Скачать руководство пользователя страница 27

26

Check

 

the

 

power

 

supply

 

and

 

the

 

electrical

 

system,

 

make

 

sure

 

the

 

electrical

 

components

 

are

good,

 

and

 

the

 

wiring

 

is

 

well.

 

If

 

there

 

is

 

a

 

damaged

 

part

 

or

 

a

 

strange

 

smell,

 

please

 

replace

 

it

 

in

time.

If

 

the

 

heat

 

pump

 

is

 

not

 

used

 

for

 

a

 

long

 

time,

 

please

 

drain

 

out

 

all

 

the

 

water

 

from

 

the

 

unit

 

and

 

seal

the

 

unit

 

to

 

keep

 

it

 

good.

 

Please

 

drain

 

the

 

water

 

from

 

the

 

lowest

 

point

 

of

 

the

 

boiler

 

to

 

avoid

freezing

 

in

 

winter.

 

Water

 

recharge

 

and

 

full

 

inspection

 

on

 

the

 

heat

 

pump

 

is

 

required

 

before

 

it

 

is

restarted.

Do

 

not

 

turn

 

the

 

power

 

‘OFF’

 

when

 

you

 

use

 

the

 

unit

 

continuously,

 

or

 

the

 

water

 

in

 

the

 

pipe

 

will

freeze

 

and

 

split

 

the

 

pipe.

Keep

 

the

 

unit

 

clean

 

by

 

means

 

of

 

soft

 

damp

 

cloth,

 

no

 

maintenance

 

is

 

required

 

by

 

the

 

operator.

It

 

is

 

recommended

 

to

 

clean

 

the

 

tank

 

and

 

e-heater

 

regularly

 

to

 

keep

 

an

 

efficient

 

performance.

Generally no maintenance is required by the operator, except below: It is recommended to set

a lower temperature to decrease the heat release, prevent scale and save energy if the outlet

water is sufficient. Keep the unit clean by means of soft damp cloth.

TROUBLESHOOTING

This section provides useful information for diagnosing and correcting certain troubles which may
occur. Before starting the troubleshooting procedure, carry out a thorough visual inspection of the
unit and look for obvious defects such as loose connections or defective wiring.
Before contacting your local dealer, read this chapter carefully, it will save you time and money.

WHEN

 

CARRYING

 

OUT

 

AN

 

INSPECTION

 

ON

 

THE

 

SWITCH

 

BOX

 

OF

 

THE

 

UNIT,

 

ALWAYS

 

MAKE

 

SURE

 

THAT

 

THE

 

MAIN

 

SWITCH

 

OF

 

THE

 

UNIT

 

IS

 

SWITCHED

 

‘OFF’.

The guidelines below might help to solve your problem. If you cannot solve the problem, consult
your installer/local dealer.

No image on the controller (blank display). Check if the main power is still connected.

One of the error codes appears, consult your local dealer.

The scheduled timer does work but the programmed actions are executed at the wrong time
(e.g. 1 hour too late or too early). Check if the clock and the day of the week are set correctly,
adjust if necessary.

ENVIRONMENTAL

 

INFORMATION

This

 

equipment

 

contains

 

fluorinated

 

greenhouse

 

gases

 

covered

 

by

 

the

 

Kyoto

 

Protocol.

 

It

 

should

 

only

 

be

 

serviced

 

or

 

dismantled

 

by

 

professional

 

trained

 

personnel.

This

 

equipment

 

contains

 

R134a

 

refrigerant

 

in

 

the

 

amount

 

as

 

stated

 

in

 

the

 

specification.

 

Do

 

not

 

vent

 

R134a

 

into

 

the

 

atmosphere:

 

R134a,

 

is

 

a

 

fluorinated

 

greenhouse

 

gas

 

with

 

a

 

Global

 

Warming

 

Potential

 

(GWP)

 

=

 1300

.

Содержание VAX HTW-ATS-O-500VAX

Страница 1: ...ENGLISH HTW ATS O 500VAX Thanks for choosing our product Please read carefully this manual before using the product OWNER S AND INSTALLATION MANUAL SANITARY WATER HEAT PUMP VAX 500 lit...

Страница 2: ...l running 16 OPERATION THE UNIT 17 User interface and operation 17 LCD icons 20 PARAMETER CHECKING AND ADUSTMENT 22 Parameter list 22 Malfunctioning of the unit and error codes 22 MAINTENANCE 25 TROUB...

Страница 3: ...aundry room or clothing room When it produces hot water it lowers the temperature and dehumidifies the room as well The advantages can be experienced particularly in the humid season Storage room cool...

Страница 4: ...ollowing safety precautions should always be taken into account Be sure to read the following WARNING before installing the unit Be sure to observe the cautions specified here as they include importan...

Страница 5: ...rvice agent or a similarly qualified person in order to avoid a hazard Improper movement or repair on the unit could lead to water leakage electrical shock injury or fire The unit is no intended for u...

Страница 6: ...ing wrong or there is a strange smell The power supply needs to be shut OFF to stop the unit otherwise this may cause an electrical shock or fire Do not put your fingers or others into the fan or evap...

Страница 7: ...INSIDE PRODUCT BOX Before starting the installation please make sure that all parts are found inside the box The Unit Box Item Image Quantity Domestic hot water heat pump 1 Operation and Installation...

Страница 8: ...7 OVERVIEW OF THE UNIT Parts and descriptions...

Страница 9: ...1420 1420 F 1845 1845 2250 2250 G 450 450 450 450 H 1140 1140 1520 1520 I 270 270 270 270 J 680 680 893 893 K 250 250 280 280 L 32 5 32 5 32 5 32 5 M 35 35 35 35 N 1230 1230 1633 1633 Remark 1 The ext...

Страница 10: ...stick Turn the power of the unit OFF and pull out the plug Drain all the water out of the tank Remove the old magnesium stick from the tank Replace the new magnesium stick Recharge the water Schematic...

Страница 11: ...at it is done with care an inclination angle up to 30 degrees is permitted both during transport and storage Ambient temperatures of 20 to 70 degrees Celsius are permitted Transport using a forklift W...

Страница 12: ...outlet pipes are connected portion airflow and capacity in heat pump unit will lose If the unit connects with air ducts it should be DN 180mm for pipes or 180mm internal diameter flexible hose Total...

Страница 13: ...stalled If not it could cause damage to the unit or even hurt people The set point of this safety valve is 0 7 MPa For the installation place please refer to the pipeline connection sketch The condens...

Страница 14: ...let the tank is full Turn off all valves and check all pipes If any leakage please repair If the inlet water pressure is less than 0 15MPa a pressure pump should be installed at the water inlet For en...

Страница 15: ...nd dehumidification Units can be placed in the laundry room or clothing room When it produces hot water it lowers the temperature and dehumidifies the room as well The advantages can be experienced pa...

Страница 16: ...e flexible type To prevent corrosion damage make sure that the materials used in the piping system are compatible 6 When installing the pipe work on the customers site any contamination of the piping...

Страница 17: ...ake sure that the power supply is normal and the wire connection is ok Check the inlet water pressure make sure that the pressure is sufficient above 0 15Mpa Check if any water flows out from the hot...

Страница 18: ...into the standby mode 2 button Press this button and keep for 2 seconds when the unit is standby the unit can be turned ON Press this button and keep for 2 seconds when the unit is running the unit ca...

Страница 19: ...the clock setting interface hour and minute icons 88 88 flash together Short press button to switch hour minute setting press the and buttons to set the exact hour s and minute s Press button again to...

Страница 20: ...he temp sensor values and EXV open steps parameters A H 2 Check the system parameters In any status press this button and hold for 5 seconds entry the system parameter checking interface Press the and...

Страница 21: ...and unit is standby If this function is disabled the fan will stop when the water temperature reaches the set point and unit is standby 3 Electrical heating The icon indicates that the electrical hea...

Страница 22: ...play the related parameter value In case any malfunction occurs this section will display the related error code 9 Time display The display shows the clock time or timer time 10 Timer ON The icon indi...

Страница 23: ...cycle period 1 12 min 8 min Adjustable 10 Electronic expansion valve adjustment 0 1 1 Adjustable 0 manual 1 auto 11 Target over heat degree 9 9 C 5 C Adjustable 12 Steps of manually adjusting the elec...

Страница 24: ...running Bright Lower tank water temp sensor failure P1 1flash 1 dark 1 The sensor open circuit 2 The sensor short circuit 3 PCB board failure 1 Check the sensor connection 2 Replace the sensor 3 chan...

Страница 25: ...h refrigerant 5 The switch damaged 6 The uncompressed gas is in refrigerant system 7 PCB board failure 1 Check if the air inlet temp is over the working limited 2 Check if the tank is full of water If...

Страница 26: ...ure 4 water flow switch failure 5 PCB board failure 1 Solar water circuit fluid infusion and exhaust 2 Related connecting wires being reconnected 3 Change the water pump 4 Change the water flow switch...

Страница 27: ...agnosing and correcting certain troubles which may occur Before starting the troubleshooting procedure carry out a thorough visual inspection of the unit and look for obvious defects such as loose con...

Страница 28: ...y to dismantle the system yourself the dismantling of the system treatment of the refrigerant of oil and other parts must be done by a qualified installer in accordance with relevant local and nationa...

Страница 29: ...28 WIRING DIAGRAM Please refer to the wiring diagram on the electric box HTW ATS O 300VAX S...

Страница 30: ...29 HTW ATS O 500VAX S...

Страница 31: ...Refrigerant type R134a Compressor Type Rotary Brand GMCC Model PJ125G1C 4DZDE PJ250M2C 4FT Fan motor Type asynchronous motor W 80 194 RPM 1280 1300 Air flow m3 h 450 900 Duct diameter mm 177 Fit flexi...

Страница 32: ...250 Packing Dimensions mm 695x695x1965 695x695x1965 750x750x2355 750x750x2355 Net Weight Kg 97 104 115 122 Gross Weight Kg 101 108 120 127 Noise level dB A 46 46 48 48 NOTES During disinfection the ma...

Страница 33: ...37 3 082 3 128 79 0 796 0 819 0 842 2 15 231 15 561 15 896 39 2 929 2 974 3 019 80 0 773 0 795 0 818 1 14 559 14 867 15 18 40 2 826 2 87 2 915 81 0 751 0 773 0 795 0 13 92 14 208 14 501 41 2 726 2 77...

Страница 34: ...7 3 589 7 230 7 28 43 89 63 11 06 98 3 482 6 219 29 42 05 64 10 67 99 3 378 5 208 30 40 28 65 10 29 100 3 278 4 197 6 31 38 61 66 9 936 101 3 182 3 187 7 32 37 01 67 9 591 102 3 088 2 178 4 33 35 49 6...

Страница 35: ...C Industria 13 Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 93 390 42 20 Fax 93 390 42 05 info htwspain com...

Отзывы: