*** REFRIGERANT : R32
2.SPECIFICATION
2.1 Performance data of Swimming Pool Heat Pump Unit
5
kW
Btu/h
kW
Btu/h
kW
kW
A
A
kW
Btu/h
kW
Btu/h
kW
kW
A
A
RPM
dB(A)
mm
3
m /h
kPa
mm
mm
kg
kg
UNIT
*
*Range
*
Heating Power Input
*Range
*
Running Current Input
*Range
**
**Range
**
Heating Power Input
**Range
**
Running Current Input
**Range
Power Supply
Compressor Quantity
Compressor
Fan Quantity
Fan Rotate Speed
Fan Direction
Noise
Water Connection
Water Flow Volume
Water Pressure Drop(max)
Unit Net Dimensions(L/W/H)
Unit Ship Dimensions(L/W/H)
Net Weight
Shipping Weight
Rated Heating Capacity(90Hz)
Rated
(90Hz)
Rated
(90Hz)
Rated Heating Capacity(90Hz)
Rated
(90Hz)
Rated
(90Hz)
Rated Heating: *Outdoor air temp: 27
ºC
**Outdoor air temp: 15
ºC
, Inlet/Outlet water temp:26
ºC
/28
ºC
,
Inlet/Outlet water temp:26
ºC
/28
ºC
During heating: Running ambient temperature: -5
ºC
~43
ºC
/24.3
ºC
/12
ºC
See the drawing of the units
See package lable
see nameplate
see package label
HTW-SWP-O-190LIO
18.70
63580
3.50~18.70
11900~63580
3.65
0.32~3.65
15.87
1.39~15.87
14.00
47600
2.55~14.00
8670~47600
3.24
0.47~3.24
14.09
2.04~14.09
22-240V~/50Hz
1
Rotary(HIGHLY)
1
850
horizontal
42-53
50
6.0
5.0
HTW-SWP-O-160LIO
16.00
54400
3.25~16.00
11050~5440
2.91
0.30~2.91
12.60
1.30~12.60
12.60
42840
2.55~12.60
8670~42840
2.80
0.44~2.80
12.17
1.91~12.17
220-240V~/50Hz
1
Rotary(HIGHLY)
1
750
horizontal
43-54
50
5.2
5.0
2.SPECIFICATION
3
Model:HTW-SWP-0-070LIO/ 110LIO
unit
mm
2.2
Dimensions for Swimming Pool Heat Pump Unit
Model:HTW-SWP-0-160LIO/ 190LIO
unit
mm
Water outlet
50
Water inlet
50
1002
190
1035
395
201
610
103
350
770
Water outlet
50
Water inlet
50
1115
182
1165
440
118
815
101
400
870