• Water Entering: After fixing all the pipes, then make the
cold and heat water-blending valve rotate to the high
temperature sector according to the clockwise direction.
And reopen the cold water pipe's water entering valve.
At this time, the electric water heater's tank will start
to enter the water. Waiting that the shower sector of the
water exiting mouth is in normal condition , which
indicates that the tank has full
y
filled with water
r:a io
During th 1
e e ectnc water heater is in the
normal operatmg procedures, the water-entenng valve
Diagram 8
of the cold water pipe's mouth-entering sector must be
in the open condition from the beginning to the end. At
this time, the water-entering valve can still make the functions of regulating
the water-existing mouth section's flowing strength and weakness. However,
the cold and hot mixed water valve can onl
y
regulate the water temperatures
and make the function of closing the water exiting.
• Putting through the power: After confirming the tank to be fully filled the
water, you can make the power source's plug insert into the outlet and put
through the power sources.
• Hot water operations: After the electric water heater normall
y
works and
heats for a long period of time,
y
ou can use the hot water in the tank,
y
ou
need to make the cold and hot mixed valve rotate with the clockwise direction
slowl
y
from the low temperature to the high temperatures in the closed
condition. And adjust it to
y
our proper temperature. At that time, the shower
mouth can come out the hot water. After finishing the uses,
y
ou can turn it to
the closed section b
y
the anti-clockwise direction and shut off the mixed
water valve.
C一
一
i-面司When adjusting the water temperature of the water-exiting mouth,
y
ou don't make the shower directly to the human body;
y
ou should test the
water temperature first to avoid burning to damages.
• Overheating Protections: Under the condition of putting through the power,
but the heating pipe won't heat from the beginning from the end. At this
time, it ma
y
appear the over heat protections (that is to make functions by the
double-positional temperature-limiting protection switch).
• Automaticall
y
balance the temperatures: When the water temperature in the
tank reaches the set one , it will automaticall
y
cut off the power and halt
heating. Meanwhile, the heating indicator will put out. The electric water
heater will be in the temperature-maintaining condition. When the water
temperature in the tank reduces to a certain one, it will automaticall
y
begin to
heat. After reaching the temperature, it will automaticall
y
cut off the power
and be in the temperature-keeping condition.It will circulate to automaticall
y
work like these.
7
Содержание JUMBO HTW-TV-100JMB
Страница 2: ...CATALOGUE...
Страница 4: ...Rated power 1500 2000W The water pressure normal use in the range of 0 2 y 0 7 MPa...
Страница 5: ...0 75MPa 0 75MPa To drain the tank perform the following steps...
Страница 6: ...0 75MPa Working indicator Control knob 1500 2000W 6 5 8 7 A 30L 50L 80L 100L 120L 150L...
Страница 11: ......