lp-606 Rev. 000 Rel. 006 Date 2.19.20
5
Filled hot water storage tanks are very heavy, and should be
located in areas that can structurally support such weight. Failure
to properly locate water storage tanks could result in property
damage, personal injury, or death.
High heat sources (sources generating heat 100
o
F / 37
o
C or
greater, such as stove pipes, space heaters, etc.) may damage
plastic components of the water heater as well as plastic vent
pipe materials. Such damages ARE NOT covered by warranty. It is
recommended to keep a minimum clearance of 8” from high heat
sources. Observe heat source manufacturer instructions, as well
as local, state, provincial, and national codes, laws, regulations
and ordinances when installing this water heater and related
components near high heat sources.
Figure 1 - Recommended Service Clearances
This water heater must be installed upright in the vertical position
as described in this manual. DO NOT attempt to install this water
heater in any other orientation. Doing so will result in improper
water heater operation and property damage, and could result in
serious personal injury or death.
E. Specifications and Dimensions
B
C
A
E
F
D
LP-606-B
08/22/18
MODEL#
GAL.
HEAT
EXCHANGER
CONNECTION
SIZE
DOMESTIC
INLET/OUTLET
APPROX.
SHIPPING
WEIGHT (lbs)
SSP-60SE
60
1" NPT
3/4" NPT
150
SSP-80SE
80
160
SSP-100SE
100
215
SSP-115SE
115
235
MODEL
GAL.
DIMENSIONS
A
B
C
D
E
F
SSP-60SE
60
23-1/2" 7-1/4" 22-1/2" 44-1/2" 52-5/8" 2-1/2"
SSP-80SE
80
23-1/2" 7-1/4" 21-1/2" 60-1/4"
69"
2-1/2"
SSP-100SE
100
27"
7-1/4" 21-1/2"
52"
61"
2-1/2"
SSP-115SE
115
27"
7-1/4" 21-1/2" 60-1/4"
69"
2-1/2"
MODEL
SOLAR HX
VOLUME
GALLONS
WATER
VOLUME OF
BACK UP
MAX. OPERATING
PRESSURE OF COIL
RECOVERY OF
BACK-UP IN
MINUTES *
FIRST
DRAW**
65 RISE 90 RISE
SSP-60SE
1
22
150 PSI
27
30
37 GAL.
SSP-80SE
1
22
63
85
68 GAL.
SSP-100SE
1
32
80
107
83 GAL.
SSP-115SE
1
32
84
112
102 GAL.
Figure 2 - SSP SE Series Water Heater Dimensions and Specifications - *NOTE: Recovery was tested with no input to coil. **NOTE: First draw was
acquired by heating the entire tank until thermostat was satisfied, then drawing until a Delta T of 15
o
F was seen at the outlet.