background image

 18

 WIRING DIAGRAM 

Содержание MICROCUT 600

Страница 1: ...HTP America Inc 180 Joey Drive Elk Grove Village IL 60007 TEL 847 357 0700 FAX 847 357 0744 MICROCUT 600 Owner s Manual...

Страница 2: ...ssume for it any other liability in connection with the sale of its machines This warranty shall not apply to any cutting machine which has been repaired or altered by unau thorized service department...

Страница 3: ...re to comply with these instructions could result in personal injury and or property damage RETAIN THESE INSTRUCTIONS FOR FUTURE REFE RENCE Note The following safety alert symbols identify important s...

Страница 4: ...ssing Do not allow the unit to be connected to the power source or attempt to operate if the unit cables work area or power cord are exposed to any form of atmospheric precipitation or salt water spra...

Страница 5: ...d slag can fly 35 feet and can pass through small cracks and openings If work and combustibles cannot be separated by a minimum of 35 feet protect against ignition with suitable snug fitting fire resi...

Страница 6: ...ring air supplied respirators Do not heat metals coated with or that contain materials that produce toxic fumes such as galvanized steel unless the coating is removed Make certain the area is well ven...

Страница 7: ...NG AND WEL DING PROCESS obtainable from the National Fire Protection Association 1 Batterymarch Park P O Box 9101 Quincy MA 02269 9101 Telephone 617 770 3000 Fax 617 770 0700 www nfpa org OSHA Standar...

Страница 8: ...SPECIFICATIONS normally again However you should wait at least ten minutes after the thermal protector opens before resuming work You must do this even if the thermal protector resets itself before t...

Страница 9: ...ac 4 RED LED CUTTING CURRENT Turns ON when torch is triggered Blinks quickly during 3 second safety pre flow prior to pilot arc ignition Blinks slowly if cutting arc is not initiated after 3 second pi...

Страница 10: ...urn cable of the cutting current may endanger the safety system and give poor cutting results Do not make a ground connection on the piece which has to be removed TORCH CONNECTION WARNING BEFORE START...

Страница 11: ...power to the system GROUND CABLE Check for a solid ground cable connection to the workpiece AUTOMATIC PURGE SYSTEM Place the ON OFF switch to the ON position The ON light will flicker momentarily as t...

Страница 12: ...matically for 3 seconds To shut off the torch simply release the control switch When the switch is released a post flow will occur If the torch trigger is pressed during the post flow the pilot arc wi...

Страница 13: ...lt when installing the cup check the threads before proceeding OPERATING FAULTS During cutting operations performance faults may arise which are not caused by the plasma cutter but by other operationa...

Страница 14: ...lace immediately Electrode Replace electrode when crater settling on emitting surface is about 5 64 WARNING Before disassembling to the torch let it cool for at least the postgas period We recommend r...

Страница 15: ...t least 72 5 PSI during purge or pre flow adjust air pressure to 65 PSI 2 Air filter or air line blocked torch blocked Replace filter cartridge Check that air line and torch leads are free of twists a...

Страница 16: ...1 60002 TORCH HEAD 1 02 60003 ELECTRODE 1 03 60004 SWIRL RING 1 04 60025 TIP 025 10 20A 1 04 60031 TIP 031 20 30A 1 04 60036 TIP 036 30 40A 1 05 60005 SHIELD CUP 1 06 60008 HANDLE MICRO 1 TORCH PARTS...

Страница 17: ...600226 COVER PANEL 1 11 21605040 CABLE CLAMP 1 11 21605041 NUT FOR CABLE CLAMP 1 12 20220120 INPUT CABLE 1 13 21600030 PLASTIC HANDLE 1 14 60180 PLASMA TORCH 1 15 21605039 CABLE CLAMP NUT 1 16 4321015...

Страница 18: ...18 WIRING DIAGRAM...

Отзывы: