10
POWER SUPPLY CONNECTION
This plasma cutter is designed to
operate on a properly grounded 230
volt, 60Hz, single-phase alternating
current (ac) power source fused with
a 30 amp time delayed fuse or circuit
breaker.
EXTENSION CORD RECOMMENDATIONS
Use an extension cord of an appropriate wire
size for the cord lenght and system voltage. Use
a cord that meets national and local cods.
Input Voltage
Phase
230VAC
1
Recommended cord
Lenght
gauge size
8 AWG
up to 33 ft (10m)
GENERATOR RECOMMENDATIONS
When using a generator with this machine, it
should produce 230VAC.
Engine Drive
Output
Performance
Rating Current
8KW
40Amps
Full
Arc
Stretch
CONNECTION TO GROUND CABLE
Connect the dinse plug to the socket and
the work cable clamp to the piece to be cut
or to the metallic workbench. Take following
precautions:
• Verify that there is a good electrical contact
particularly if insulated or oxidated coated
sheets are cut.
• Make ground connections as close as
possible to the cutting area. The use of the
metallic structures which are not part of the
workpiece, such as the return cable of the
cutting current, may endanger the safety
system and give poor cutting results.
• Do not make a ground connection on the
piece which has to be removed.
TORCH CONNECTION
WARNING!: BEFORE STARTING THE
CUTTING OPERATIONS VERIFY THAT THE
PARTS ARE PROPERLY ASSEMBLED BY
INSPECTING THE HEAD OF THE TORCH
AS SHOWN ON PARAGRAPH “TORCH
MAINTENANCE”
LOCATION AND HANDLING OF THE
POWER SOURCE
• Choose location verifying that there is a good
air fl ow and no dust, smoke or gas is present.
• Make sure that obstacles do not prevent
the cooling air fl ow out of front and rear
openings of the machine.
• Arrange an open space of at least 16ft around
the machine.
• In the case the machine has to be moved,
always disconnect the plug from the outlet
and gather the cables and pipes so as not to
damage them.
COMPRESSED AIR
A source of clean, dry air or nitrogen must be
supplied to your plasma cutting unit. The supply
pressure must be between 72.5 and 150 psi. The
fl ow rate is approximately 3.5 cu.ft./min. Failure
to observe these precautions could result in
excessive operating temperatures or damage to
the torch.
An air regulator is included with the unit with
optimum pressure setting set to 65 PSI.
NOTE: THE REGULATOR SHOULD NEVER
BE SET ABOVE 87 PSI.
PLASMA CUTTER INSTALLATION