HTP Everlast C2X030 Скачать руководство пользователя страница 2

lp-565 Rev. 002 Rel. 005 Date 11.19.18

2

The following defined terms are used throughout this manual to 

bring attention to the presence of hazards of various risk levels or to 

important product information.

DANGER 

indicates an imminently hazardous situation which, if not 

avoided, will result in serious personal injury or death.

WARNING 

indicates a potentially hazardous situation which, if not 

avoided, could result in personal injury or death.

CAUTION 

indicates a potentially hazardous situation which, if not 

avoided, may result in moderate or minor personal injury.

CAUTION used without the safety alert symbol 

indicates a 

potentially hazardous situation which, if not avoided, may result in 

property damage.

NOTICE 

is used to address practices not related to personal injury.

Foreword

This manual is intended to be used in conjunction with other literature 

provided with the water heater. This includes all related control 

information. It is important that this manual, all other documents 

included in this system, and additional publications be reviewed in 

their entirety before beginning any work.
Installation should be made in accordance with the regulations of 

the Authority Having Jurisdiction, local code authorities, and utility 

companies which pertain to this type of water heating equipment.
Authority Having Jurisdiction (AHJ) – The AHJ may be a federal, state, 

local government, or individual such as a fire chief, fire marshal, chief 

of a fire prevention bureau, labor department or health department, 

building official or electrical inspector, or others having statutory 

authority. In some circumstances, the property owner or his/her agent 

assumes the role, and at government installations, the commanding 

officer or departmental official may be the AHJ.

NOTE: 

HTP reserves the right to modify product technical specifications 

and components without prior notice.

For the Installer

This water heater must be installed by qualified and licensed personnel. 

The installer should be guided by the instructions furnished with the 

water heater, and by local codes and utility company requirements.
This water heater complies with the energy efficiency requirements of 

10 CFR § 431.110 (Commercial Water Heaters). It does not comply with 

10 CFR § 430.32(d) (Consumer Water Heaters).

Installations Must Comply With:

Local, state, provincial, and national codes, laws, regulations, and 

ordinances.
The latest version of the 

National Electrical Code, NFPA No. 70

.

IMPORTANT SAFETY INSTRUCTIONS

When using electrical appliances, basic safety precautions to 

reduce the risk of fire, electric shock, or injury to persons should 

be followed, including:
1. READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER.
2. This water heater must be grounded. Connect only to a properly 

grounded outlet. See Part 4 – Wiring, this manual, for grounding 

details.
3. Install or locate this water heater only in accordance with the 

provided installation instructions.
4. Use this water heater only for its intended use as described in 

this manual.
5. Do not operate this water heater if it has been damaged or 

dropped.
8. This water heater should be serviced only by qualified service 

personnel. Contact the water heater installer or a qualified service 

agency for examination, repair, or adjustment.

SAVE THESE INSTRUCTIONS

NOTE: 

If the water heater is exposed to the following, do not 

operate. Immediately call a qualified service technician.

 

1. Fire

 

2. Damage

 

3. Water

Failure to follow this information could result in property damage, 

severe personal injury, or death. 

For Your Records

Write the Product Model and Serial Numbers:
Model # ___________________________________________
Serial # ____________________________________________
These numbers are listed on the product ratings label.

Keep this manual and information for future reference.

From the Uniform Plumbing Code 2000 - Section 510 -  

Protection From Damage

1. Water heaters generating a glow, spark or flame capable of 

igniting flammable vapors may be installed in a garage, provided 

the pilots, burners or heating elements and switches are at least 

eighteen (18) inches (457 mm) above the floor level.
2. Where such water heaters installed within a garage are enclosed 

in a separate, approved compartment having access only from 

outside of the garage, such water heaters may be installed at floor 

level provided the required combustion air is also taken from the 

exterior of the garage. Fuel burning water heaters having sealed 

combustion chambers need not be elevated.
3. All water heaters installed in areas where they may be subjected 

to mechanical damage shall be suitably guarded against such 

damage by being installed behind adequate barriers or by being 

elevated or located out of the normal path of a vehicle using any 

such garage.
4. In seismic zones 3 and 4, water heaters shall be anchored or 

strapped to resist horizontal displacement due to earthquake 

motion. Strapping shall be at points within the upper one-third 

(1/3) and lower one-third (1/3) of its vertical dimensions. At the 

lower point, a minimum distance of four (4) inches (102 mm) shall 

be maintained above the controls with the strapping.
5. An water heater supported from the ground shall rest on level 

concrete or other approved base extending not less than three (3) 

inches (76 mm) above the adjoining ground level.
6. When an water heater is located in an attic, attic-ceiling 

assembly, floor-ceiling assembly, or floor-subfloor assembly where 

damage may result from a leaking water heater, a watertight pan 

of corrosion resistant materials shall be installed beneath the 

water heater with a minimum three-quarter (3/4) inch (20 mm) 

diameter drain to an approved location.

Содержание Everlast C2X030

Страница 1: ...iable for typographical errors in literature NOTE TO CONSUMER PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE 272 Duchaine Blvd New Bedford MA 02745 www htproducts com lp 565 Rev 002 Rel 005 Date 11...

Страница 2: ...nnect only to a properly grounded outlet See Part 4 Wiring this manual for grounding details 3 Install or locate this water heater only in accordance with the provided installation instructions 4 Use...

Страница 3: ...rt 8 Troubleshooting 15 Limited Warranty 16 Customer Installation Record Form 18 Do not use this water heater for anything other than its intended purpose as described in this manual Doing so could re...

Страница 4: ...the water heater as centralized to the piping and electrical system as possible Also locate the water heater and domestic water piping where it will not be exposed to freezing temperatures All piping...

Страница 5: ...onal more frequent maintenance may be required If you suspect that your water is contaminated in any way discontinue use of the appliance and contact an authorized technician or licensed professional...

Страница 6: ...69 23 1 4 8 UL 1453 3 4 NPT 151 120oF 48 8 C 181oF 82 8 C 200oF 93 3 C EVC100 100 7 1 4 52 61 27 206 EVC115 115 60 1 4 69 224 Table 2 Specifications and Dimensions Refers to Electrical Specifications...

Страница 7: ...n Figure 3 for the electric water heater to operate properly Failure to install these fittings properly will result in improper water heater operation possible substantial property damage and increase...

Страница 8: ...the water heater and check valve and must be sized for the entire water volume of the hot water system See piping Applications Other methods of controlling thermal expansion are available Check with t...

Страница 9: ...RE TO RE INSPECT THE T P VALVE AS DIRECTED COULD RESULT IN UNSAFE TEMPERATURE AND OR PRESSURE BUILD UP WHICH CAN RESULT IN PROPERTY DAMAGE SERIOUS PERSONAL INJURY OR DEATH Do not thread a cap or plug...

Страница 10: ...perage requirements The voltage requirement and dedicated wattage load for the heater is specified on the rating label of the water heater Consult your local power company to determine if your electri...

Страница 11: ...Heating elements will be damaged if energized for even a short time while tank is dry Failures due to dry firing ARE NOT covered by warranty A Combination Thermostat and High Limit Control ECO After...

Страница 12: ...attempting heating element replacement will result in property damage severe personal injury or death due to electric shock STEP 2 Run hot water at a faucet in the system When it runs cold shut off th...

Страница 13: ...ter faucet s once all air has been bled from the system when water runs freely Make certain that the heater is completely full of water before restoring power Periodically At least twice a year Check...

Страница 14: ...ve operation and possibly result in substantial property damage severe personal injury or death 9 10 14 16 1 3 4 5 6 7 7 8 8 8 10 11 12 13 15 9 16 T R A P N O I T P I R C S E D M E T I 1 JUNCTION BOX...

Страница 15: ...thermostat setting or replace 3 Tighten wire connections Improper wiring Check and rewire per Wiring Detail Not Enough Hot Water Heater undersized Reduce rate of heater use Defective element s Check a...

Страница 16: ...er heater shall then be deemed to have commenced on the date of manufacture of the water heater and NOT the date of installation of the water heater and be covered by the unexpired portion of the Stan...

Страница 17: ...hase of the product or an original certificate of occupancy for a new home 2 Clear pictures or video of the following a Serial number tag sticker b The product c The product issue failure whenever pos...

Страница 18: ...allation Installation Address Product Name Serial Number s Comments Installer s Code Name Installers Phone Number Signed by Installer Signed by Customer Installation Notes IMPORTANT Customer Please on...

Отзывы: