HTD MC-66 Multi-Zone Скачать руководство пользователя страница 16

15

How to Use

 

(CONT.)

Changing the Source Name on the KC7:

The KC7 keypad has the ability to display user-created names for each source on the LCD screen of each KC7 keypad.

These custom names must first be created within the HTD Valet Home Control app. If the names have not been created in the 

Valet Home Control app or the user has chosen not to use the Valet Home Control app in conjunction with the KC7, then the 

source names displayed on the KC7 will default to SRC1, SRC2, SRC3, etc.

Instructions on how to change the source names within the Valet Home Control app can be found within the Valet Operations 

Manual (located on the HTD site or included with the purchase of your HTD Valet gateway). Or you can contact HTD at 

info@

htd.com or toll free 1-866-HTD-AUDIO (483-2834)

 and we will gladly walk you through the setup instructions.

Using the KC7 Keypad

Source Selection Buttons:

Select a source by pressing either of the two source buttons to navigate through sources.

The two source buttons navigate in opposite directions. One advancing to the next source the other reverting to the previ-

ous source.

 

Volume Control:

Press the volume up or volume down button to control the volume. You can press these buttons once for an incremental 

increase or decrease, or press and hold the buttons down for continuous increase or decrease. There are 60 volume level 

settings giving you the ability to find a perfect volume level at any time of day or night.

 

Power On/Off/Mute:

Press the power button once to turn the keypad on. Press it again to mute the sound in that zone. While muted, “MUTE” 

will display on the KC7 screen. To un-mute, press the power button again or press either of the volume buttons. Note that 

you may have to first wake up the keypad if it is in sleep mode by pressing any button.

Press and hold the power button for approximately 1 second to power off the keypad. If keypad is in “sleep” mode, it must 

first be “awakened” to then power off. If volume is muted, the keypad can be powered off as normal with out being un-

muted.

Power ALL OFF:

It is possible to turn off every keypad connected to the controller by simply pressing the power button on any keypad and 

holding it for approximately 3 seconds. Note that the keypad you are pressing will turn off after 1 second; continue holding 

for an additional 2 seconds to turn off all zones.

 

Party Mode / ALL ON

At any time, it is possible to force all of the zones connected to the same controller to turn on with the same source se-

lected. When a keypad is powered on, simply press and hold the source button you want to hear for approximately 4 sec-

onds. All of the keypads, even those that were previously powered off, will begin playing the same source at the volume 

level previously set on each keypad.

Once all of the keypads have been set, they are again immediately available for individual control, i.e. a keypad in any 

zone continues to have control over its own zone so that a different source could be selected or that zone could be turned 

off.

Using the Remote Control

 (KC6 or KC7)

We provide a simple, credit-card sized infrared remote control for controlling the basic functionality of the keypad. Simply 

point this remote control at any keypad to conveniently change sources, control volume, mute, or power on and off in that 

zone.

Using Your Own Remote Control

 

(KC6 or KC7)

You may want to use your own universal or learning remote control to control the keypad functions as well as the functions 

of the centralized components. To do this, you will need to purchase at least one of our remote controls and then follow the 

instructions provided with your learning remote control to teach it to control volume, source selection, power, and mute.

Содержание MC-66 Multi-Zone

Страница 1: ...dio Control Owner s Manual MC 66 Multi Zone Controller MCA 66 Multi Zone Controller Amplifier Home Theater Direct Toll free 866 HTD AUDIO 483 2834 www htd com info htd com Copyright Home Theater Direct Inc V 07 06 17 ...

Страница 2: ...ower Cord Protection Route the power cord so that it is not likely to be walked on or pinched by items placed upon or against them paying particular attention to the plugs receptacles and the point where the cord exits from the appliance Cleaning Unplug the appliance from the wall outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use a cloth lightly damp ened with water for cle...

Страница 3: ...areil 11 Utilisez uniquement des fixations accessoires spécifiés par le fabricant 12 Utilisez seulement avec un chariot un support un trépied une console ou table spécifié par le fabricant ou vendu avec l appareil Lorsque vous utilisez un chariot soyez prudent lorsque vous déplacez l ensemble chariot appareil pour éviter les blessures en cas de chute 13 Débranchez cet appareil durant les orages ou...

Страница 4: ...3 This Page is Intentionally Blank ...

Страница 5: ... you have any questions please call us toll free at 1 866 483 2834 during business hours M F 8am 6pm CST We re here to help and to make sure you are getting the most out of your new whole house audio system IMPORTANT WARNINGS AND HELPFUL TIPS Please note that while we refer to Cat5e throughout this manual Cat5 and Cat6 can also be used with equal effectiveness 1 Never connect or disconnect Cat5e c...

Страница 6: ...er Multiroom Controller MC 66 Zone Status 1 2 3 4 5 6 Power button and blue indicator light Zone status lights blue indicate when a zone is active IR Repeater Outputs Con nect to single or dual IR emit ters to pass IR signal to other audio components Stereo pre amp outputs for each zone fixed and variable connect to separate 12 channel amplifier RJ45 connectors for connecting Cat5e cable to keypad...

Страница 7: ... all keypads Power Button Multi function but ton used to power on power off and mute the keypad Can also be used to power off all keypads Volume indicator lights Select from up to six centrally located sources LCD Screen displays selected source volume level and setup menu options Two RJ45 con nectors Use one for connect ing Cat5 cable or Cat5e or Cat6 to control ler Optionally use the other RJ45 ...

Страница 8: ...ther connector is used for connecting up to two total keypads in each zone This is discussed in more detail later in this section Once connected keypads will control the zone in which the Cat5e cable is inserted on the controller Daisy Chaining Keypads It is possible to connect a maximum of two keypads into any one zone by daisy chaining the keypads together using the extra RJ 45 connector on the ...

Страница 9: ... drywall 3 Install KC6 KC7 4 Install KC6 KC7 plate 5 Check distance between KC6 KC7 plate and Drywall Vol Vol Power Mute Source Vol Vol Power Mute Source Vol Vol Power Mute Source Vol Vol Power Mute Source 2 Apply tape directly to drywall 4 Install KC6 KC7 plate Vol Vol Power Mute Source 3 Install KC6 KC7 5 Check distance between KC6 KC7 plate and Drywall Vol Vol Power Mute Source Vol Vol Power Mu...

Страница 10: ... multi channel amplifier using stereo RCA type patch cables as shown in Figure 4 In most cases you should set the Fixed Variable switch to Variable This allows the keypad to control the volume level in that zone Select ing the Fixed switch position is recommended when you set up multiple sub zones see Sub zones pg 9 in one zone where each of the pairs of speakers in that zone are independently con...

Страница 11: ...C 1 IR OUT IR IN SOURCE INPUT RS232 INTERFACE KEYPAD PORTS 1 2 3 4 5 6 L R 4 3 2 1 5 6 12V DC TRIGGER OUT IN VARIABLE FIXED ZONE 1 L R L R L R L R L R L R ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 VARIABLE FIXED Power Multiroom Controller MC 66 Zone Status 1 2 3 4 5 6 FUSE T1A 250V AC 120V 60Hz Power Consumption 70W IR OUT IR IN SOURCE INPUT RS232 INTERFACE KEYPAD PORTS 1 2 3 4 5 6 L R 4 3 2 1 5 6 12V DC...

Страница 12: ...gger output will be inactive and the DMA 1240 1275 will automatically return to sleep mode Please note that the Power Button on the front of the DMA 1240 1275 should be pressed in with the blue power indicator light illuminated Trigger mode using the included Trigger cable is preferred We generally don t recommend use of the Auto setting for this application Auto mode detects the presence of an au...

Страница 13: ...hin the emitter is located on the bottom portion of the emitter This is why the emitters should be attached on top of the device s receiving eye that you wish to control FUSE T1A 250V AC 120V 60Hz Power Consumption 70W IR OUT IR IN SOURCE INPUT RS232 INTERFACE KEYPAD PORTS 1 2 3 4 5 6 L R 4 3 2 1 5 6 12V DC TRIGGER OUT IN L R PRE OUT ZONE1 FIXED VARIABLE L R PRE OUT ZONE2 FIXED VARIABLE L R PRE OU...

Страница 14: ...and balance settings will be the same as you programmed them Repeat for all zones Using the KC6 Keypad Source Selection Buttons Select a source by pressing on one of the 6 source buttons Volume Control Press the volume up or volume down button to control the volume You can press these buttons once for a incremental increase or decrease or press and hold the buttons for continuous increase or decre...

Страница 15: ...ating to appropriate feature the KC7 screen will display the feature balance treble or bass that you have current control over along with a graphic below showing the current setting See Balance Example Screen Figure 10 Use the volume buttons to make adjustments to current settings and use the source buttons on the face of the keypad to navigate to the next or previous feature Adjusting Font Color ...

Страница 16: ...t is in sleep mode by pressing any button Press and hold the power button for approximately 1 second to power off the keypad If keypad is in sleep mode it must first be awakened to then power off If volume is muted the keypad can be powered off as normal with out being un muted Power ALL OFF It is possible to turn off every keypad connected to the controller by simply pressing the power button on ...

Страница 17: ...mplifier or volume control Steps for Splicing Wires 1 Strip back about of insulation on the ends of the two wires to be spliced together 2 Strip back about of insulation on the end of a 6 10 single length of the same wire 3 Twist the three bare wire ends together tightly 4 Solder the twisted connection using electrical solder 5 After the solder cools wrap plastic electrical tape tightly around the...

Страница 18: ...s firmly into the plug Inspect that each wire is flat and even at the front of the plug Check the order of the wires Double check again Check that the jacket is fitted right against the stop of the plug Carefully hold the wire and firmly crimp the RJ 45 with a special RJ 45 crimping tool Check the color orientation check that the crimped connection is not about to come apart and check to see if th...

Страница 19: ...haring Sources Across Multiple Controllers Figure 14 CD Player 1 Tuner CD Player 2 Power Multiroom Controller MC 66 Zone Status 1 2 3 4 5 6 FUSE T1A 250V AC 120V 60Hz Power Consumption 70W IR OUT IR IN SOURCE INPUT RS232 INTERFACE KEYPAD PORTS 1 2 3 4 5 6 L R 4 3 2 1 5 6 12V DC TRIGGER OUT IN ZONE 1 L R L R L R L R L R L R ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 VARIABLE VARIABLE FIXED FIXED Power Mult...

Страница 20: ...n mode The amplifier in a zone will shut down until the problem has been resolved This is usually an indication of a short in the speaker cable or speaker connection If you have any questions please contact HTD at info htd com or toll free 1 866 HTD AUDIO 483 2834 Specifications Stereo Zones Stereo Inputs Pre amp outputs switchable between Fixed and Variable for each zone RS232 connection for Vale...

Отзывы: