HTC GL 40 D
Usage
2.0
17
6. Fit the Longopac holder to the dust extractor by turning it until it locks into
place.
7. Secure the Longopac holder using the strap.
8. Seal the bag with a tie at the bottom.
9. Pull down the Longopac roll to the recommended length, around 500 mm.
4.5
Installing extra ventilation hose
To improve the air while grinding, an extra ventilation hose can be installed on the dust
extractor. This extra ventilation option should be used while grinding floors that give
rise to toxic gases or if the room is very poorly ventilated.
Tip!
Only use the extra ventilation hose, which must be at least 3", when required,
since the dust extractor's capacity is reduced when the hose is installed.
1. Using a suitable camlock coupling, fasten the ventilation hose to the outlet for
ventilation hose connection, see Figure 3-2, page
. Contact HTC for
recommended connections or consult the Product Catalogue.
2. Place the free end of the ventilation hose outdoors by pulling it through a
window or a door.
4.6
Operation
4.6.1
Starting and stopping the dust extractor
1. Place the dust extractor where you want to start the vacuuming work.
2. Connect the dust extractor to the mains supply. Use suitable cables for the dust
extractor.
3. Start the dust extractor by pressing the "I" button.
4. Stop the dust extractor by pressing the "O" button.
4.6.2
Manual cleaning of the filter using the slide gate
Tip!
To ensure effective cleaning of the filter, all gaskets on the dust extractor should
be checked to ensure that they are undamaged and that they seal tightly.