prevent the electric shock. 

 Function choosing switch: Used to select the function, range or turn 

on or turn off the clamp meter. 
 

Function Description 

 

ACA measurement. 

 

ACV,

 

DCV

 

measurement.

 

Press

 

“SELECT”

 

to

 

switch

 

the

 

measurement

 

mode.

 

Press

 

“Hz/DUTY”

 

to

 

switch

 

to

 

Frequency/Duty

 

cycle

 

measurement

 

mode

.

NCV 

Non-contact voltage test. 

Ω

 

Press “SELECT” to switch to Diode, Continuity, 

Capacitance and Resistance measurement mode. 

Hz Frequency 

measurement. 

/

℃ ℉

 

Temperature measurement. Press “SELECT” button to switch 

to 

 or 

 Function key. 

 LIGHT 

button: Backlight and Clamp light control key. Press   

LIGHT button more than 2 seconds, backlight and clamp light will be 
on. Press this button again, the backlight and clamp light will be off. 
The backlight will auto turn off after 5 seconds if not pressing it again. 

SELECT

 button: Function selection key. Press this button to select the 

measurement mode: Under “

” mode, choose DC or AC. Under 

Ω

” mode, choose “

”  “

” “

 

Ω

measurement.   

HOLD

 button:    Press “HOLD” button, the current testing value will 

be kept displayed on the LCD, and press this button again to cancel this 
function. When this function works, user cannot do any new test. 

REL 

button: Press this button to clear the readings and enter into the 

Relative measurement mode and a “REL” symbol will be displayed on 
the LCD. Press this button again to cancel this function. 

 LCD: Displaying measurement value and unit.

   

 

No. Symbol 

Description 

 

Indicates negative readings. 

 

AC AC 

measurement. 

 

DC DC 

measurement. 

 

Auto Auto 

range. 

 

Null. 

 

Diode test. 

 

Continuity beeper is on. 

 

HOLD Data 

hold 

 

REL Relative 

measurement. 

 

Low battery indication.     

11

 

hFE

 

NCV 

nF

uF 

M

k

 

mV, V 

uA

 mA

 A 

Hz

kHz

MHz

Null.

 null. 

Non-contact voltage testing. 

nF

uF 

M

k

 

mV, V 

uA

 mA

 A 

Hz

kHz

MHz 

V/

 input terminal: Measurement inputs positive terminal (red 

test lead).   
COM input terminal: Measurement inputs negative terminal (black 
test lead). 

 Carrying belt. 

4.2 ACA MEASUREMENT 

(1) Turn the rotary switch to 

 

range. 
(2) Open the clamp jaw and grip one 
wire and get the reading directly.                 
To get the most precise reading, should user put the wire in the 
middle of the close jaw   (refer to the picture 3).                  
Note:

 

 

1.

 

Firstly users should select the highest range, if users are 

not sure about the range of current under test, and then select the 
proper range based on displaying value. 

2.

 

DO NOT input the current higher than the limit, or it 

would damage the meter. 

4.3

 

ACV MEASUREMENT 

(1)

 

Turn the function swift to 

 range.  

(2)

 

Insert the black test lead into “COM” 

terminal, and the red one into “V/

” terminal. 

(3)

 

Connect the test leads into the circuit and get 

the measurement value from the LCD. (refer to 
picture 4) 
                                                                                        (picture 4) 
Note: 
1. DO NOT input the voltage over the limit, or it would damage 
the meter.

 

2. Be careful while measuring a high voltage circuit. Do not touch 
the high voltage circuit. 
 

4.4 DCV MEASUREMENT 

(1) Turn the function swift to DCV range.   
(2) Insert the black test lead into “COM” terminal, and 
the red one into “V/

” terminal. 

(3) Connect test leads to the test point. LCD will display 
polarity and voltage of the test point connected by the 
red test lead. (refer to picture 5)                                                 
Note: 
1. DO NOT input the voltage over the limit, or it would damage 
the meter.

 

2. Be careful while measuring a high voltage circuit. Do not touch 
the high voltage circuit. 

4.5 NCV MEASUREMENT 

NCV 

Static electricity or other sources of energy   

may randomly trigger the sensor. The result is only 
for reference. 
4.5.1

 

Turn the rotary switch to NCV position. 

4.5.2

 

Hold the top of the meter very close to the 

voltage 

source 

under 

test.                               

4.5.3 If voltage is present, the NCV LED will flicker rapidly or 
intermittently 

NOTE:                 

1.

 Even no indication when NCV test, there might still voltage be. 

Содержание CM-2007

Страница 1: ... To avoid electric shock and damage to the meter please disconnect the input signal and remove away the test leads before opening the cover Avoid the water leakage into the cover 2 2 3 DO NOT do any test if the cover hasn t been completely installed or screws not tightened up 2 2 4 DO NOT input the value higher than the limit at every range 2 2 5 DO NOT input any voltage at Resistance range 2 2 6 ...

Страница 2: ... 100pF 4uF 1nF 40uF 10nF 200uF 5 0 reading 10 100nF Overload protection 250V RMS NOTE DO NOT input any voltage value at this range 3 2 8 Frequency test Range Accuracy Resolution 100Hz 0 5 reading 5 0 1Hz 1kHz 0 1Hz 10kHz 1Hz 100kHz 10Hz 1MHz 100Hz 10MHz 1kHz Input sensitivity 0 7V Overload protection 250V RMS 3 2 9 Temperature test Range Accuracy Resolution 40 750 400 1 0 5 400 1 5 15 1 Sensor K t...

Страница 3: ...easurement inputs positive terminal red test lead COM input terminal Measurement inputs negative terminal black test lead Carrying belt 4 2 ACA MEASUREMENT 1 Turn the rotary switch to range 2 Open the clamp jaw and grip one wire and get the reading directly To get the most precise reading should user put the wire in the middle of the close jaw refer to the picture 3 Note 1 Firstly users should sel...

Страница 4: ... the red test leads is for positive pole LCD displays capacitance value Note 1 Don t input voltage or current at Capacitance range 2 In order to assure the accuracy please press REL to clear the reading before testing 3 There is only the auto range mode under the capacitance range 4 The capacitor must be completely discharged before testing 5 The reading of 200uF range will take more than 15 secon...

Страница 5: ...OLD key signal appears Replace battery Big error Value Replace battery The specifications are subject to changes without prior notice The content of this manual is regarded as correct If users find out any mistakes or omissions please kindly contact the manufacturer The manufacturer will not be responsible for accidents and damage caused by improper operations The functions described in this User ...

Отзывы: