VEGA74
EN - 37
10.3. REFERENCE GUIDELINES
Safety:
IEC/EN61010-1, IEC/EN61557-1
EMC :
IEC/EN61326-1
EMC ambient of use :
industrial, Class A, Group 1
Technical documentation:
IEC/EN61187
Safety of measuring accessories: IEC/EN61010-031, IEC/EN61010-2-032
Insulation:
double insulation
Pollution level:
2
Protection index:
IP40
Measurement category:
CAT IV 300V to ground, CAT III 350V to ground
max 600VAC between inputs
Network quality:
EN50160
10.4. GENERAL CHARACTERISTICS
Mechanical characteristics
Size (L x W x H):
225 x 165 x 75mm ; (9 x 6 x 3in)
Weight (batteries included):
1.2kg ; (42 ounces)
Power supply
Battery type:
6 x1.2V rechargeable batteries NiMH type AA
6x1.5V alkaline batteries type AA IEC LR06 MN1500
Low battery indication:
low battery symbol “ ” on the display
Battery life:
> 500 tests for each function
> 6 hours in recording
Recharging time:
approx. 12 hours
External adapter:
100-240VAC, 50/60Hz / 15VDC, CAT IV 300V
Auto Power OFF:
after 5 minutes idling (if activated)
Miscellaneous
Display:
TFT, color, capacitive touch-screen, 320x240mm
Aggregation time:
2s to 30min selectable
Memory for snapshots:
999 memory locations, 3 levels of markers
Memory for recordings:
8MB (not expandible), max 49 recordings
Connection to PC:
optical/USB port
No cable connection:
WiFi connection
10.5. ENVIRONMENT
10.5.1. Environmental conditions for use
Reference temperature:
23° ± 5°C ; (73°F ± 41°F)
Operating temperature:
0 ÷ 40°C ; (32°F ÷ 104°F)
Allowable relative humidity:
<80%RH
Storage temperature:
-10 ÷ 60°C ; (14°F ÷ 140°F)
Storage humidity:
<80%RH
Max operating altitude:
2000m (6562ft)
This instrument satisfies the requirements of Low Voltage Directive 2014/35/EU
(LVD) and of EMC Directive 2014/30/EU
This instrument satisfies the requirements of European Directive 2011/65/EU (RoHS)
and European Directive 2012/19/EU (WEEE)
10.6. ACCESSORIES
See the attached packing list.