QUICKLAN 6050N
EN - 10
Symbol
on the display
INVERTED PAIR
Cables of pair 3-6 inverted
Symbol
on the display
CROSSED PAIRS
Cables of pair 3-6 crossed
with cables of pair 4-5
Symbol
on the display
GENERIC ERROR
(MISWIRE)
Cables of pair 1-2
inverted
Cable 4 of the pair 4-5
short-circuited with
cable 8 of pair 7-8
Screen S open
Symbol
on the display
SPLIT PAIRS
Correspondence pin to pin
is maintained, but the
cables of pairs 3-6 and 4-5
are physically crossed
CAUTION
The instrument identifies the SPLIT error, making the concerned pairs flash
and showing symbol
“
SPLIT
”
on the display.
The error condition SPLIT is detected by the instrument
only in case no
other error condition is present
and with a cable length of at least 5m (15ft).