QuickLAN
6050
EN - 5
4. OPERATING INSTRUCTIONS
4.1. INSTRUMENT
DESCRIPTION
4.1.1. Control
description
1
9
7
5
2
3
8
TEST
nF
ft
m
11
7
6
4
1
10
2
3
4
12
Fig. 2: Instrument and remote identifiers #1 ~ #4
LEGEND:
1. LCD Display
2. TEST key
3. Power key
4. SET key
5. LENGTH measurement key
6. WIREMAP test key
7.
▼
▲
keys
8.
↵
ENTER key
9. M (Memory) R (Read) key
10. RJ45 jack
11. Remote Identifiers #1 ~ #4
(Identifiers #2, #3, #4 optional)
12. BNC connector
4.2. FAILURES
DETECTED
4.2.1. SHORTS
Range of short detection:
0 to 350m (0 to 999ft)
Accuracy of distance to a short:
UTP/FTP:
7% + 3m (7% + 10ft)
Coaxial Cables:
10% + 10m (10% + 30ft)
Assumes short is 0
Ω
.
4.2.2. OPENS
Range of open detection:
0 to 350m (0 to 999ft)
Accuracy of distance to an open : UTP/FTP:
10% + 1m (10% + 3 ft)
4.2.3. SPLIT PAIRS
Range of detection:
2 to 350m (6 to 999ft)
Split pair part of the cable must be at least 2 meters (6ft) in length and greater than 10% of
the total cable length.
4.2.4. COAX
termination
measurements
Any loop resistance value between 5 and 350
Ω
is interpreted as a termination resistance.
Resistance value below 5
Ω
is considered shorts and resistance value greater than 350
Ω
is
not displayed.
Содержание QuickLAN 6050
Страница 1: ...Copyright HT ITALIA 2011 Release 1 03 17 10 11 6050 QuickLAN Manuale d Uso User manual...
Страница 2: ......
Страница 3: ...Indice generale General index ITALIANO IT 1 ENGLISH EN 1...
Страница 4: ......
Страница 5: ...Copyright HT ITALIA 2011 Versione IT 1 03 17 10 11 ITALIANO Manuale d Uso...
Страница 18: ......
Страница 19: ...Copyright HT ITALIA 2011 Release EN 1 03 17 10 11 ENGLISH Instruction manual...