HSP GmbH Zum Handwerkerhof 2 90530 Wendelstein Tel. 09129 / 2852-0 Fax: 09129 / 2852-11 Web: www.hsshsp.de EMAIL: [email protected]
NTG-3000 Operating Instructions Version 2.11
Page 9 of 18
9
LEDs
LED
Description
Color
POWER
Lit when operating voltage is present
Green
STATUS
To indicate operation and errors (see 15.1)
Green
ERROR
To indicate error conditions (see 15.1)
Red
Ethernet Link/Activity Not lit
No link
Yellow
Lit
Link
Flashing
Activity / network traffic
Ethernet Speed
Not lit
10Base-T
Green
Lit
100Base-TX
10
Startup
The device must be configured as described in Section 8 prior to startup. The supply voltage
can then be connected. Once the initialization phase is complete, cyclic measured value
acquisition starts automatically and, if an Ethernet link is available, the transducer starts to
send a continuous stream of measured values to the permanently programmed target IP
address (see Section 14.1).
At the same time, the values can be queried via the PROFIBUS interface (see Section 14.2).