Maintenance
16
2018-06-11
FM 169 A&M Instr. for Gamma type Z..D Rev.01
distributed by
10 Maintenance
Around all rotating parts (e.g. GX shaft) there is a risk of being pulled
in, and of clothing or body parts being caught up and trapped. There is
also a risk of crushing around the moving carriage and the rack-and-
pinion drive.
For this reason, lubrication of the linear unit may only be carried out
while it is moving slowly (max. 0.025 m/s), and for any cleaning work
the linear unit drive must be shut down and secured against being
restarted.
All mounted ball bearings are sealed and maintenance-free.
Remove excessive dust and dirt from the cover band and other
parts of the linear unit regularly.
10.1 Lubrication
Influencing factors
The following influencing factors are important for an accurate
regulation of lubrication intervals:
Load
Speed
Motion sequence
Operating temperature
Degree of contamination
Short lubrication
intervals
Short lubrication intervals are required for:
operation under the influence of dust and dampness
a heavy load
high speed (up to V
max
)
short strokes
Initial lubrication
After commissioning, carry out the initial lubrication. The basic
lubrication has already been carried out by the manufacturer.
Refer to the lubrication regulations on the following pages.