Enter Load SET Mode by pressing the Setting key in Load Mode view only.
Use the arrow key to cycle through load modes before long pressing SET to
save and exit. Short pressing ESC will exit without saving.
In the temperature display interface, enter the temperature unit setting mode
by long pressing the setting button. You can switch between
℉
(Fahrenheit)
and
℃
(Celsius) by pressing up and down arrow key. Long press the setting
button to confirm saving and exit, and short press the ESC key to exit the
setting without saving.
Load Mode Settings
Load Mode View
Setting Load Mode
Long [ SET ] press
save and exit setup
short
[ ESC] press
exit without saving
[ SET ]
Temperature Unit Setting
Advanced Battery Settings
Pressing the Setting key to enter SET mode.Choose Lithium or User mode,
short press the Setting key again to cycle through each parameter view.
Use the up and down arrow key to adjust parameter value, then long press
Setting key to save.
For Battery Type: Li
Low Temperature Proctection(Frozen Charge Forbid)
Battery Type: USER
System Voltage
Equalize Charge Voltage
Boost Charge Voltage
Float Charge Voltage
Equalize Charge Interval
Over-discharge Recovery
Over-discharge Voltage
Battery Type: Li
System Voltage
Charge Voltage
Over-discharge Voltage
Over-discharge Recovery
Frozen Charge Forbid = OFF
Frozen Discharge Forbid Range = 5±9
℉
/-15±5
℃
When the temperature reaches the protected
on/off range, the low-temperature protection will
automatically turn on/off after 30 seconds.
Frozen Charge Forbid Range = 32±9
℉
/0±5
℃
For Battery Type: USER
ON
Frozen Forbid = ON
Mode
Definition
Description
0
1~14
15
16
Daylight Auto-Control
Daylight On/Timer Off
Manual Mode
Testing Mode
DC load turns on when no daylight is detected.
DC load turns on when no daylight is detected.
DC load turns off according to timer.
DC load turns on/off by pressing the Return key.
DC load turns on and off in a quick succession.
DC load stays on.
Always On
17