DMX512 Chain with Termination
A DMX terminator is recommended for installations where the DMX cable has to run a
long distance or is in an electrically noisy environment (e.g. discos). The terminator
prevents corruption of the digital control signal by electrical noise. The DMX terminator is
simply an XLR plug with a 120
Ω
resistor between pins 2 and 3, which is then plugged into
the XLR output socket of the last device in the chain.
Please see illustrations.
•
DMX512 Start Address
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This start
address is the channel number from which the device starts to “listen” to the DMX controller. Enter the correct
number and read it from the display located on the base of the
VDP1401RGLD4
.
You can use the same starting address for a whole group of devices or enter an individual one for every device.
When all devices have the same address, all the
VDP1401RGLD4
s will “listen” to the control signal on one particular
channel. In other words: changing the settings of one channel will affect all devices simultaneously. If you set
different addresses, each device will “listen” to a separate channel number. Changing the settings of one channel will
only affect the device in question.
In the case of the 4-channel
VDP1401RGLD4
, you will have to set the start address of the first
VDP1401RGLD4
to
1, the second
VDP1401RGLD4
to 5 (1 + 4), the third to 9 (5 + 4) and so on.
7. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections.
3. Moving mechanic parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts.
8. Contact your dealer for spare parts if necessary.
8. Technical Specifications
Power Supply
max. 230VAC/50Hz
Power Consumption
50W
Fuse
F2A, 250VAC (5 x 20mm) (order code
FF2N
)
Laser Type
Green
40mW @ 532nm, DPSS laser
Red
100mW @ 650nm
DMX Channels
4
Connection
XLR for DMX mode of master/slave
Dimensions
285 x 120 x 80mm
Total Weight
2.5kg