Adjusting the duration time
The length of time that the unit remains switched on after activation can
be adjusted from 10±5 seconds to 4±1 minutes. Rotating the TIME knob
anticlockwise from (+) to(-) reduces the duration time. Note: Once the light
has been triggered by the PIR sensor any subsequent detection will start
the timed period again from the beginning.
Adjusting the LUX control level
The LUX control module has a built-in sensing device (photocell) that
detects daylight and darkness. Rotate the LUX knob anticlockwise from
light ( ) to dark ( ). The ( ) position will allow the floodlight to work day
and night, and the ( ) position works only at night. You can set the unit to
operate at the desired level by adjusting the LUX knob.
How to change into manual control mode
1. When power is first switched on,the PIR detector enters into the WARM-
UP period for about 1 minute, then automatically changes into AUTO
MODE.
2. During AUTO MODE, by switching the ON/OFF main switch off & on
twice in about 3 seconds, the PIR detector will automatically change into
MANUAL MODE. In MANUAL MODE, the flood light will remain ON for 8
hours. It will not be affected by duration time and Lux control level. After
8 hours, the PIR detector will change back to AUTO MODE.
3. During MANUAL MODE, by switching the ON/OFF main switch off & on
twice in about 3 seconds, the PIR detector will automatically change into
AUTO MODE.
4. During AUTO MODE or MANUAL MODE, by switching off the ON/OFF
main switch over 10 seconds and then on again, the PIR detector will
reset to WARM-UP period.
Cat no.
LFS0110WBL
LFS0130WBL
Supply voltage
230-240V a.c. 50Hz
Input power
11W
32W
Power ouput
10W
30W
Lumens ouput
730lm
2250lm
Colour
tempertaure
Cool white 4000K nominal
Mounting height
>
2m (recommended)
Protection class
Class 1
Weatherproof
rating
IP44
Size (mm)
115 x 130 x 200 mm
228 x 188 x 270 mm
Weight
(excl packaging)
0.7kg
1.7kg
Power cord
requirement
H05RN-F 3G 1mm
2
PIR sensor
Standby power
<
1.0W
Detection range
12m (max), 180° scan
Time adjustment
10 ±5 sec to 4 ±1 min
Switching function
Auto mode / manual override
POWER ON
1
2
3
AUTO MODE
MANUAL MODE
Specifications