background image

White wire to light

Blue wire to neutral

N

White wire to light

Green-yellow to light

Green-yellow to earth

Brown wire to switch

L

Setting the controls

 

With floodlight fully installed by electrician and  

power on

1.  Turn the LUX control knob to light ( ) position, turn the wall switch 

on and wait 30 seconds for the control circuit to stabilise. Ensure the 
TIME control knob is set at minimum (-).The lamp on the sensor light 
will now switch on and will remain on for about 10sec.

2.  Direct the sensor toward the desired scanning area by adjusting 

the elbow joint and swivel joint on the sensor arm. Important: 
loosen all lock nuts and screws on sensor arm and wall mount 
bracket before making any adjustments.

3.  Have someone move across the centre of the area to be scanned and 

slowly adjust the angle of the sensor arm until the unit senses the 
moving person, causing the lamp to switch on. (Refer Fig.1 B)

4.  Adjust time control to required setting.

5.  To set the light level at which the lamp will automatically switch 

“On”, turn the LUX control knob from daylight to night. If the lamp 
is required to switch on earlier, e.g. dusk, wait for the desired light 
level, then slowly turn the LUX control knob towards daylight while 
someone walks across the centre of the area to be detected. When 
the lamp switches on, release the LUX knob. You may need to 
make further adjustments to achieve your ideal light level setting.

Important: To avoid dust build-up and ensure proper functioning 
of the sensor light, wipe the sensor lens lightly with a damp 
cloth every 3 months. Never modify the unit, there are no user 
serviceable parts inside.

Dial settings show  

TEST MODE

Fig. 5

Fig. 4

Fig. 1B 

Highest Sensitivity

Fig. 1A 

Lowest Sensitivity

2m

4M

8M

approx.180˚

12M

Installation

Installing a wall switch adjacent to the power source is recommended.

1.   Remove mounting bracket from the fitting and use to mark position 

on the wall/ceiling.

2.   Mount the bracket on the wall/ceiling. Ensure the method of fixing 

can support up to a 10kg weight.

3.   Reattach fitting to the bracket.* Do not tighten bolts completely to 

allow for mains wiring termination. 
*Ensure that cord gland faces downwards in the final mounting 
position as shown in Fig.2

4.   Choose rubber-sheathed 3-core circular cord, H05RN-F 3G 1mm

2

 

(not supplied) for the mains wiring.

5.   Remove junction box cover, strip insulation from cord and insert in to 

cord gland. Wire up as shown in Fig 4.

6.   Replace junction box cover and tighten screws to ensure a 

weatherproof seal. Tighten gland.

7.  Orient fitting to desired position and tighten bolts completely.

8.   DO NOT MEGGER TEST

Fig. 3 Detection Area