CAUTION: 

Regulations concerning the discharge of air must be fulfilled. Local building codes may require venting to the outside. Locate in accordance 
with the requirements of the Wiring Rules AS/NZS 3000 relating to damp situations. 

Note: Steam will only be removed if there is sufficient flow of air through the room. Ensure adequate inlet openings in the room are provided, 

for example through windows, vents or under the door. Air-flow paths from room inlets to fan should ideally pass over surfaces where 
condensation may form.

2   Mounting 

These exhaust fans are designed primarily for wall-mounting. They may be vented in to a cavity wall or in to the roof space in the ceiling. 

Alternatively, the fan may be ducted through an outside wall (with the addition of ducting and an outside grille). Protrusions into wall/ceiling 
cavity are as per below figures.

The flaps of the Auto-Shutter are driven by a thermoactuator. Due to this, the flaps will take time to open/close when the exhaust fan is 

switched on/off. 
Time to Open: 30 – 60 seconds  

 

Time to Close: 120 – 200 seconds

Draft Stopper

Duct

Ceiling

96mm

160mm

250mm

Wall/Ceiling

Wall/Ceiling

Draft Stopper

Duct

Ceiling

96mm

160mm

250mm

Wall/Ceiling

Wall/Ceiling

Fan with duct

Fan with draft stopper

Fan with auto shutter and duct

Fan with auto shutter

Fan only

Draft Stopper

Duct

Ceiling

96mm

160mm

250mm

Wall/Ceiling

Wall/Ceiling

Ceiling

Duct

Fan with Auto-Shutter & duct

310mm

150mm

Fan with Auto-Shutter

Wall/Ceiling

Auto-Shutter

ROOF VENT CAP

ROOFING

When fitted, the duct outlet must be the same height or lower 

than the exhaust fan. 

The duct must not be installed vertically into a roof vent cap  

–  the product is not designed or intended for this type  

of installation.