1.  This product must be installed and used as per these instructions.
2.  This product should only be cleaned with a damp cloth. Cleaning agents and solvents should not be used.
3.  This product is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be 
supervised to ensure that they do not play with the appliance.

4.  This product is intended for household use and similar purposes. It is not suitable for use in and environment heavily laden with dust. Under these conditions 

the life of the fan motor can be significantly reduced.

5.  This product should not be enclosed in thermal insulation as it may cause the unit to overheat.
6.  This product has been designed to operate in ambient temperatures -10°C to 40°C.
7.  This product contains no serviceable parts and no attempt should be made to repair it. If the product is faulty it should be discarded.
8.  Airflows listed in this product indicate the product performance. Refer to the BCA (Building Code of Australia), or similar, for the appropriate airflow required 

for a particular installation.

9.  Ventilation products must have an adequate source of external air to ensure correct performance.
10. Consideration must be taken in the installation of ducts to ensure that condensation that will form in the duct will not run back into the fan housing.
11. Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances.
12. This product has been designed for domestic or similar uses and is not suitable for a commercial installation.
13. This product is not suitable for installation in hazardous and/or corrosive areas.
14. The material in this product may vary in colour from batch to batch. Colour matching from one batch to another cannot be guaranteed.
15. This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. Such intellectual property remains the property of 

HPM Legrand in all cases.

16. HPM Legrand reserves the right to modify the specification of this product at any time.

Warranty

HPM Legrand warrants this product for a period of 3 years from 
the date of purchase. 

These goods come with guarantees that cannot be excluded 
under the Australian and New Zealand Consumer Laws. You 
are entitled to a replacement or a refund for a major failure and 
for compensation for any other reasonably foreseeable loss or 
damage. You are also entitled to have the goods repaired if the 
goods fail to be acceptable quality and the failure does not amount 
to a major failure. 

See the Warranty card enclosed with this product for further 
details.

Customer Service

For all Customer Service and Technical Support  
please call Monday to Friday during business hours.

HPM Legrand Australia 
1300 369 777 

www.hpm.com.au

HPM Legrand New Zealand 
0800 476 009 

www.hpm.co.nz

ABN: 31 000 102 661

A)   Line   drawings   for   Installa*on:         

Figure   9   

Delete   this   

line   

A)   Line   drawings   for   Installa*on:         

Figure       

AFTER   

BEFORE   

figure 8

figure 9

Содержание EFD01RDWE

Страница 1: ... White Supply Voltage 230 240V a c 50Hz Power Rating 40W max Max Airflow Rate Non ducted 330m3 hr Max Airflow Rate Ducted Ø150mm x 3m 250m3 hr Protection Class Class II Duct Requirement Ø150mm Ceiling Cut out Size Ø298mm Projection into Ceiling 190mm Protrusion from Ceiling 26mm Grille Size Ø372mm 350 x 350 mm EFD01RDWE EFD01SQWE EFD01RDWE EFD01RDMS EFD01SQWE ...

Страница 2: ...ted directly above any part of the bath or shower recess or enclosure The unit must be installed within zones 2 and 3 only For further information refer to AS NZS 3000 7 Unit Orientation The unit must be installed to ensure the housing outlet and ducting is oriented in parallel to any roofing structures or supports Refer to image below for correct installation orientation Orientation which forces ...

Страница 3: ...at one end and insert a pencil at the other end and scribe a circle figure 2 3 Cut out around this line figure 3 4 Remove grille from the exhaust fan 5 Attach duct adaptor to duct with duct tape figure 4 6 Ensure that a power outlet is installed in the ceiling near the intended position of the exhaust fan Ensure that power to the outlet is off Plug the exhaust fan into this outlet figure 5 7 Attac...

Страница 4: ...the duct will not run back into the fan housing 11 Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances 12 This product has been designed for domestic or similar uses and is not suitable for a commercial installation 13 This product is not suitable for installation in hazardous and or corrosive areas 14 The material in t...

Отзывы: