The unit shall be installed horizontally in the ceiling in accordance with example images shown below to ensure intended operation and rated performance.  
When fitted, the duct outlet must be the same height or lower than the exhaust fan. 
The duct must not be installed vertically into a roof vent cap - the product is not designed or intended for this type of installation.

Installation

1.  Determine position in ceiling where the exhaust fan is required to be installed (figure 1). 
2.  Use the template provided to draw a circle. To do this, insert a thumb tack at one end and insert a pencil at the other end and scribe a circle (figure 2).
3.  Cut out around this line (figure 3).
4.  Remove grille from the exhaust fan.
5.  Attach duct adaptor to duct with duct tape (figure 4).
6.  Ensure that a power outlet is installed in the ceiling near the intended position of the exhaust fan. Ensure that power to the outlet is off. Plug the exhaust fan 

into this outlet (figure 5).

7.  Attach duct adaptor to the exhaust fan outlet (figure 6).
8.  Insert the unit into the cavity (figure 7).
9.  With the unit in place, turn the toggles (4x) clockwise and tighten the screws until the clamps securely grip the ceiling (figure 8).
10. Push grille onto unit and click into position (figure 9).

figure 1

figure 2

figure 3

figure 4

Figure       

figure 6

figure 7

figure 5

Содержание EFD01RDWE

Страница 1: ... White Supply Voltage 230 240V a c 50Hz Power Rating 40W max Max Airflow Rate Non ducted 330m3 hr Max Airflow Rate Ducted Ø150mm x 3m 250m3 hr Protection Class Class II Duct Requirement Ø150mm Ceiling Cut out Size Ø298mm Projection into Ceiling 190mm Protrusion from Ceiling 26mm Grille Size Ø372mm 350 x 350 mm EFD01RDWE EFD01SQWE EFD01RDWE EFD01RDMS EFD01SQWE ...

Страница 2: ...ted directly above any part of the bath or shower recess or enclosure The unit must be installed within zones 2 and 3 only For further information refer to AS NZS 3000 7 Unit Orientation The unit must be installed to ensure the housing outlet and ducting is oriented in parallel to any roofing structures or supports Refer to image below for correct installation orientation Orientation which forces ...

Страница 3: ...at one end and insert a pencil at the other end and scribe a circle figure 2 3 Cut out around this line figure 3 4 Remove grille from the exhaust fan 5 Attach duct adaptor to duct with duct tape figure 4 6 Ensure that a power outlet is installed in the ceiling near the intended position of the exhaust fan Ensure that power to the outlet is off Plug the exhaust fan into this outlet figure 5 7 Attac...

Страница 4: ...the duct will not run back into the fan housing 11 Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances 12 This product has been designed for domestic or similar uses and is not suitable for a commercial installation 13 This product is not suitable for installation in hazardous and or corrosive areas 14 The material in t...

Отзывы: