background image

Warranty

HPM Legrand warrants this product for a period of 3 years from the date of purchase. 
These goods come with guarantees that cannot be excluded under the Australian and  
New Zealand Consumer Laws. You are entitled to a replacement or a refund for a major 
failure and for compensation for any other reasonably foreseeable loss or damage.  
You are also entitled to have the goods repaired if the goods fail to be acceptable quality 
and the failure does not amount to a major failure. See the Warranty card enclosed with 
this product for further details.

Customer Service

For all Customer Service and Technical Support  
please call Monday to Friday during business hours.

HPM Legrand Australia 

HPM Legrand New Zealand

1300 369 777 

0800 476 009

www.hpm.com.au 

www.hpm.co.nz

ABN: 31 000 102 661

LE06397AP

A

3

4

5

  Installation

  Cleaning

  Optional Accessories

Remove all packaging from the product before commencing installation. Ensure the circuit has been isolated from the 240V mains before 

commencing work. 

1.   Choose a suitable mounting location. There must be adequate clearances in the wall/ceiling to accommodate the Draft-stopper and/or 

ducting. Refer to section 2 for further information.

2.  If ducting through the wall to the outside, refer to instructions in the wall duct kit. Note: the wall kit is available separately, please refer  

to Optional Accessories section.

3. Time-delay module is available separately, please refer to Optional Accessories section.
4.  Make a circular 110mm hole in the wall/ceiling.
5.  Remove front cover / fascia by removing fixing screw and cap on the underside of the cover.
6.  Remove draft-stopper if not required. Note that the draft-stopper (when fitted) has an effect on the airflow.
7. Make the electrical connections (as per Figures below). 

8. Ensure orientation of fan is with arrow pointing

up.

9. Fix fan firmly to the wall with the 4 screws provided. 
10. Replace front cover/fascia and tighten fixing screw. Replace cap.
11.  Switch on and test function. Use a paper tissue held against fan inlet to verify suction.

The exhaust fan grill should be cleaned every 6 months to prevent dust build-up. Ensure the fan is switched off from the mains supply before 

removing the fascia.

R621/4D – 100mm wall duct kit 
EF100/150TD – Time delay module allows the fan to run for a set period, adjustable between 1 - 29 mins, after the switch has been turned off.

LS

N

L

3

2

1

Fan 

mounting 

orientation

Cable entry  

from rear

Cord entry from 

side for plug and 

lead (knock-out 

provided)

LS   Switched Active 

from wall switch

N  Neutral
L    Unswitched Active 

(only used when 

timer module is 

fitted)

Fixing screw 

position of fascia

  Figure 1.

  Figure 2. Fan with timer module and light fitting

Disclaimers

1. This product must be installed and used as per these instructions. 2. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, 
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised 
to ensure that they do not play with the appliance. 3. This appliance is intended for household use and similar purposes. It is not suitable for use in an environment heavily laden with dust. Under 
these conditions the life of the fan motor can be significantly reduced. 4. This product contains no serviceable parts and no attempt should be made to repair this product. If the product is faulty it 
should be discarded. 5. This product must be cleaned periodically from dust and other contaminants with a damp cloth. Aggressive cleaning agents and solvents should never be used. 6. Airflows 
listed in this product indicate the product performance. Refer to the BCA (Building Code of Australia), or similar, for the appropriate airflow required for a particular installation. 7. Ventilation 
products must have an adequate source of external air to ensure correct performance. 8. Consideration must be taken in the installation of ducts to ensure that condensation that will form in the 
duct will not run back in to the fan housing. 9. Precautions must be taken to avoid the back-flow of gases into the room from the open flue of gas or other fuel-burning appliances. 10. This product 
has been designed for domestic or similar uses and is not suitable for a commercial installation. 11. This product utilises intellectual property in the form of registered designs, trademarks, and/or 
patents. Such intellectual property remains the property of HPM Legrand in all cases. 12. HPM Legrand reserves the right to modify the specification of this product at any time.

Active

L

N

LS

Neutral

Connection from rear – bring mains wiring through  

cable entry hole.

Connection from side (Fan only) – use twin flat core 

(H03VV-H2) or circular core (H05VV-F) 2 x 0.75mm

2  

and place under cable clamp provided.

LS

N

L

3

2

1

Timer