EF100SQWE
Standard square
100mm wall fan
Wall Exhaust Fan, 100mm
Cat. EF100SQWE, EF100SQSWE, EF100RDWE
Instruction Manual
1
2
Product Specifications
Mounting
For indoor use only.
*
Measured with
Φ
100mm ducting.
Airflow will be reduced with bends in duct, squashing of duct,
restrictions on replacement air entering the room to be ventilated,
or pressure-differentials between the room and outside air.
The length of the duct will have an effect on the airflow. When fitted,
the wall kit (R621/4D) must be at the same height or lower than the
exhaust fan.
EF100SQSWE
Slimline square
100mm wall fan
EF100RDWE
Round
100mm wall fan
Model
EF100SQWE
EF100SQSWE EF100RDWE
Supply Voltage
230-240VAC 50Hz
Power Rating
14W
Wall/Ceiling Cut-out Size
Ø110mm
Class of Protection
Class II
Time delay adjustment
(with time delay module
fitted, sold separately)
1 – 29 min adjustable
IP Rating
IP44
IP24
IP24
Fascia
Size
158x158mm
158x158mm
Ø190mm
Protrusion 30mm
17mm
17mm
Weight (excl packaging) 500g
450g
450g
Model
EF100SQWE
EF100SQSWE EF100RDWE
Exhaust Fan
1 pc
1 pc
1 pc
Draft Stopper
1 pc
1 pc
1 pc
Instruction Manual
1 pc
1 pc
1 pc
Warranty Card
1 pc
1 pc
1 pc
Wall Mount screws & Plugs
1 set
1 set
1 set
Contents
Model
EF100SQWE
EF100SQSWE
EF100RDWE
Draft Stopper
with
without
with
without
No duct
68
94
81
105
Wall kit R621/4D*
(350mm of duct)
33
68
48
75
1m of duct*
33
60
46
66
Airflow* (m
2
/hr)
Please read carefully: Read through these instructions completely before commencing installation. Retain for future use.
This product should be installed by a licensed electrical contractor or similarly qualified person.
These exhaust fans are designed primarily for wall-mounting.
They may be vented in to a cavity wall or in to the roof space in the
ceiling. Alternatively, the fan may be ducted through an outside wall
(with the addition of ducting and an outside grille). Protrusions into
wall/ceiling cavity are as per below figures.
CAUTION:
Regulations concerning the discharge of air must be fulfilled.
Local building codes may require venting to the outside. Locate in
accordance with the requirements of the Wiring Rules AS/NZS 3000
relating to damp situations.
Note: Steam will only be removed if there is sufficient flow of air
through the room. Ensure adequate inlet openings in the room are
provided, for example through windows, vents or under the door. Air-
flow paths from room inlets to fan should ideally pass over surfaces
where condensation may form.
Draft Stopper
Duct
Ceiling
80mm
120mm
200mm
Wall/Ceiling
Wall/Ceiling
Draft Stopper
Duct
Ceiling
80mm
120mm
200mm
Wall/Ceiling
Wall/Ceiling
Draft Stopper
Duct
Ceiling
80mm
120mm
200mm
Wall/Ceiling
Wall/Ceiling
Fan with duct
Fan only
Fan with
draft stopper