50
Code
PROGRAMMER LCD DISPLAY
EFFECT OF FAULT
POSSIBLE CAUSE
SET/CLEAR CONDITIONS
77
Supervisor Fault
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake;
ShutdownPump.
1) The Supervisor has detected a
mismatch in redundant readings.
2) Internal damage to Supervisor
microprocessor.
3) Switch inputs allowed to be within
upper and lower thresholds for over
over 100 milliseconds.
Set:
Mismatched redundant
readings;
damaged Supervisor; illegal
switch inputs.
Clear:
Check for noise or
voltage drift in all switch
inputs; check connections;
cycle KSI.
78
Supervisor Incompatible
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
ShutdownInterlock;
ShutdownDriver1;
ShutdownDriver2;
ShutdownDriver3;
ShutdownDriver4;
ShutdownPD;
FullBrake;
ShutdownPump.
1) The main OS is not compatible
with the Supervisor OS.
Set:
Incompatible software.
Clear:
Load properly matched
OS code
or update the Supervisor code;
cycle KSI.
82
Bad Calibrations
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
FullBrake;
ShutdownPump.
1) Internal controller fault.
Set:
Internal controller fault
detected.
Clear:
Correct fault; cycle KSI.