NOTE: 

By default, iLO obtains the management

IP address and subnet mask from the DHCP
server in your network. The hostname found on
the iLO tag is automatically registered with DNS
server in your network. If the DHCP configuration
is not possible or the system is not found in DNS,
use the direct attach method to configure iLO with
a static IP address.

e.

Using the default user information provided on the
iLO Network Settings tag, log on to iLO and
launch a remote console to the storage system.

NOTE: 

In the event that the initial configuration is for a

two node cluster, ensure you have either a direct
connection or iLO connection to both file controllers.

For detailed instructions about access methods, see the

HPE Storage File Controller Administrator Guide

.

Cabling for the cluster heartbeat connection

A two-node Storage File Controller fail over cluster is
configured during initial setup. An ethernet cable is
connected to port 4 between the two file controllers as
depicted in the figure below. This is also known as the
cluster network interconnect. During the setup, you will
be prompted to set up a two-node cluster. This network
connection is used for establishing the initial
communication between the servers.

Figure 5: Connecting the servers

Connecting HPE 3PAR Storage array

Connect the 3PAR storage array to:

Storage File Controllers

3PAR storage array management connection

Connecting HPE 3PAR Storage array to Storage
File Controllers

Before you begin the HPE Storage File Controllers
installation, ensure that other storage connections (Fibre
Channel or iSCSI) for the HPE 3PAR Storage Array are
connected. Use the suggested cabling guidelines to
connect the 3PAR storage array. For more information
on cabling, see the 

HPE 3PAR StoreServ Cabling

Configuration Guide

.

Connecting HPE 3PAR Storage array to 3PAR
storage array management connection

Connect the HPE 3PAR Storage array management
network connections to the network. The 3PAR array
management IP address and login credentials is needed
during the initial configuration tasks (ICT) of the Storage
File Controllers. During the configuration in ICT, the
Storage File Controllers are able to communicate with
the 3PAR storage array management IP address. For
more information, see the 

HPE Storage File Controller

Administrator Guide

.

Connecting HPE MSA Storage

Connect the MSA array to:

HPE Storage File Controllers

(Recommended) A remote management host

Connect the MSA Storage to Storage File
Controllers

Direct connect and switch connect environments are
supported between the MSA storage and the file
controllers. The MSA storage host connection ports can
be either Fibre Channel or iSCSI for clustered
environments. For switch-connect configurations,
connect cables from the MSA controller host connection
ports to the switch ports and from the switch ports to the
file controllers.

For cabling examples, including connecting directly to a
server, see the 

HPE MSA Cabling Configuration Guide

.

Page 7     

Содержание Q9D43A

Страница 1: ...Controller Q9D44A HPE Storage Performance File Controller 1 Unpack the HPE Storage File Controller Before you begin ensure that you have the following items in the shipping box Hardware Components HP...

Страница 2: ...p 1 of the HPE Storage File Controller chassis 1 Inside 1 of the HPE Storage File Controller chassis 1 Pull out serial number tab 1 on the product 1 The COA label Product ID key is required when The W...

Страница 3: ...f the rack must rest firmly on the floor Ensure that the rack has anti tip measures such as floor bolting anti tip feet ballast or a combination of the measures as specified by the rack manufacturer a...

Страница 4: ...ized bracket location 4 Secure the HPE Storage File Controller to the rack rails using thumbscrews on the front bezel as shown in Figure 3 and Figure 4 Figure 3 Secure HPE Storage File Controller to t...

Страница 5: ...rough DHCP If your environment does not support DHCP use a KVM and configure iLO to use a static IP address For instructions see the HPE Storage File Controller System Administrator Guide The 4 x 1GbE...

Страница 6: ...ore information see the following Microsoft articles http blogs msdn com b clustering archive 2012 03 30 10289577 aspx https docs microsoft com en us windows server failover clustering prestage cluste...

Страница 7: ...ction Connecting HPE 3PAR Storage array to Storage File Controllers Before you begin the HPE Storage File Controllers installation ensure that other storage connections Fibre Channel or iSCSI for the...

Страница 8: ...ls available during ICT Ensure that the HPE Nimble storage array is installed and cabled before starting the configuration of the HPE Storage File Controllers 4 Power Up To power up the server use one...

Страница 9: ...After the second node is located you will see the language selection on the second node is selected based on the primary node language selection The license screen is displayed for the second node NOT...

Страница 10: ...Controller Administrator Guide Next Steps Ensure that you follow all the steps in the ICT tasks starting with the first task Use the question mark on the top right side of each task for additional on...

Отзывы: